4. Louver control
4-1. Vertical airflow direction louver control
Each time the button is pressed, the air direction range will change as below:
1
2
3
4
5
6
7
1
2
3
4
5
6
7
• Remote controller display is not changed.
• Vertical airflow direction is set automatically as shown, in accordance with the type of operation
selected.
Cooling/dry mode
: Horizontal flow 1
Heating mode
: Downward flow 7
• During AUTO operation, for the first a few minutes after beginning operation, airflow will be hori-
zontal 1; the air direction cannot be adjusted during this period.
The airflow direction setting will temporarily become 1 when the temperature of the airflow is low at
the start of the Heating mode.
• After beginning of AUTO/HEAT mode operated and automatic defrosting operation, the airflow will
be horizontal 1. However, the airflow direction cannot be adjusted at beginning AUTO operation
mode.
4-2. Swing operation
• To select vertical airflow swing operation
When the swing signal is received, the vertical airflow direction louver starts to swing.
– Swinging range
• Cooling mode/dry mode/fan mode: 1 ↔ 7
• Heating mode: 1 ↔ 7
– When the indoor fan is S-LOW or stop mode, the swing operation is interrupted and it stops at
either upper end or bottom end.
4-1. Vertical airflow direction louver control
- (04-12) -
4. Louver control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Содержание ABHG54KRTA
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2020 04 16 SR_CH01_AB007EG_01 ...
Страница 12: ...2 2 Outdoor unit 01 6 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Страница 13: ...2 TECHNICAL DATA AND PARTS LIST 2020 11 16 SR_CH02_AB007EG_02 ...
Страница 31: ...3 TROUBLESHOOTING 2020 07 29 SR_CH03_AB007EG_01 ...
Страница 34: ......
Страница 95: ...4 CONTROL AND FUNCTIONS 2020 07 29 SR_CH04_AB007EG_01 ...
Страница 97: ...8 8 High temperature and high pressure release control 04 29 CONTENTS continued ...
Страница 98: ......
Страница 129: ...5 FILED WORKING 2020 07 29 SR_CH05_AB007EG_01 ...