(10) Method to set Pause and to display Cleave Angle, Gap Dif., and Offset
• Refer to [Splice Option] (Page 44).
(11) Mismatch between Estimated splice loss and Actual splice loss
• The estimated loss is a calculated loss, so it can be used for reference only.
• The optical components of the splicer may need to be cleaned.
• When using the standard mode, adjust [Est. Coef.] and [Minimum Loss]. To adjust these
parameters, refer to the parameter settings of the other splice modes stored in the
database area.
3. Tube-heater Operation
(1) Fiber protection sleeve does not shrink completely
• Extend the heating time. Refer to [Editing Heater Mode] (Page 40).
(2) Heater symbol on display blinks
• Pressing the key during heating causes the symbol to blink. The tube heater is
turned off if the HEAT key is pressed again. If 2 seconds have gone by without pressing
the HEAT key again, the symbol stays on continuously and the heater returns to its
normal state. The symbol will disappear when the heat cycle is completed.
• If the heating temperature does not reach its desired setting, the symbol blinks and the
alarm sounds. If this happens, contact your nearest sales agency.
(3) Fiber protection sleeve adhered to heating plate after shrinking
• Use a cotton swab or a similar soft tip object to push and remove the sleeve.
(4) Method to initialize heating condition of Heater mode
• Refer to [Editing Heater Mode] (Page 40).
(5) Method to cancel heating process
• does not cancel the heater. Press twice to cancel the heating process.
4. Supervising
(1) What functions can be disabled
• Refer to [Menu Lock] (Page 53).
(2) Method to lock “selection” or “editing” of Splice or Heater mode
• Refer to [Menu Lock] (Page 53).