44
Splice Menu
4. Splice Option
Common parameters for all splicing and tube heating modes can be set.
(1) Select [Splice Option] in [Splice
Menu] to display [Splice Option]
menu.
(2) Select a parameter to be changed.
(3) Press
to change values, and press
to enter.
Setting parameters
Parameter
Description
Auto Start
If “Auto Start” is set to "ON", splicing starts automatically as
soon as the wind protector is closed. Fibers should be prepared
and placed into the splicer in advance.
Pause
If "Pause” is set to “ON”, splicing operation pauses when fibers
are forwarded to the gap-set position. Cleave angles, gap, and
offset are displayed during the pause. Press
key twice to
display results table.
Fiber Image on Screen
PAUSE
FINISHED
Setting the fiber image on the screen in Pause / Finish statement.
X
DATA : Composite display X-axis and result of cleave
angle, offset, and gap.
Y
DATA : Composite display X-axis and result of cleave
angle, offset, and gap.
DATA
: Display result of cleave angle, offset, and gap.
Splice Option
Select [Splice Option]
in the [Splice Menu]
Содержание KSP75-FP-005468
Страница 2: ......