41
Splice Menu
Heater mode parameters
Parameter
Description
Sleeve type Sets sleeve type. List of all heater modes are displayed. Select a mode
in the list and this is copied to a user-programmable mode.
Mode Title1
Title of a heater mode that is displayed in the lower right part of the
monitor during the splicing/heating process. Max number of
characters used is 5.
Mode Title2 Description of a heater mode in the [Sleeve Type] screen. Max number
of characters used is 13.
Heater
Control
Sets the heater control sequence.
RIBBON40: For 40mm protection sleeve for ribbon fiber, up to 4.
SINGLE60: For 60mm protection sleeve for single fiber
SINGLE40: For 40mm protection sleeve for single fiber
Heat Time
Sets heating time from the beginning to the end (cool-down
completion). Heating time is automatically adjusted with atmospheric
conditions, such as ambient temperature. Heating time may be longer
or shorter than the [Heat time] set.
Heat Temp
Sets heating temperature. If Nylon coated fiber is used with 8mm
cleave length, the Nylon coating may melt if [Heat Temp] is over 190
degrees Celsius.
Finish Temp
Sets the finish temperature. When heater approaches this temperature,
the buzzer beeps, announcing the sleeve is cooled down and is ready to
be removed from the heater.
Caution If the [Finish Temp] is set for over 100 degrees Celsius, the
buzzer beeps before the sleeve is cooled and ready. Hot
sleeves easily deform and can cause some residual stress at
the splice point once the sleeve is finally cool.