68
Questions and Troubleshooting
1. Power Supply
(1) Power does not turn off when pressing
• Press and hold the key for 2 or 3 seconds.
(2) Few splices can be made with a fully charged battery pack
• If the power saving function is not enabled, the battery power degrades faster. Refer to
[Power Save] (Page 52). Always enable it to conserve power usage.
• The battery pack has reached the end of its service life. Install a new battery pack.
• The battery pack uses a chemical reaction to produce power. The capacity decreases
when it is exposed to lower temperatures, especially at lower than 0
°
C.
• At high altitude, the arc discharge current is increased. In this condition, battery power
degrades faster due to larger power consumption.
(3) “POWER” LED on Battery Charger blinks during battery recharge
• Atmospheric temperature is too high (more than 40
°
C), or the battery pack is charged
under exposure to sunlight.
• The battery pack has a fault or has reached the end of its service life. Install a new
battery pack. If the LED blinks again after install, contact your nearest sales agency.
(4) Method to change the power saving function settings
• Refer to [Power Save] function on page 52.
(5) Battery indicator is not displayed / Power saving function does not work
• When using the AC adapter, the function does not work.
• Battery pack indicator on the battery pack does not work correctly.
(6) Incorrect indication of battery indicator
• The indicator display serves as a reference only.
• Battery Pack Indicator on the battery does not work correctly.
2. Splicing Operation
(1) Confirmation of splicing procedures
• Refer to [Splicing procedure] (Page 20).
(2) Error message appears on monitor
• Refer to [Error Message List] (Page 62).
Содержание KSP75-FP-005468
Страница 2: ......
Страница 9: ...5 Warning and Caution BLANK PAGE ...