![FujiFilm FRENIC5000G11S Series Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/fujifilm/frenic5000g11s-series/frenic5000g11s-series_technical-information_2343268035.webp)
1-29
Chapter 1
3. Wiring Diagram
Caution
The information described in this document is for the purpose of selecting the
appropriate product only. Before actually using this product, be sure to read the
Instruction Manual carefully to ensure proper operation.
1
3.3 Wiring diagram using options
(1) 230V/460V
FRENIC5000G11S : 1/4 to 1HP / 1/2, 1HP
L1/R
L2/S
L3/T
U
V
W
G
G
G
M
N(-)
P1
(X9)
(CM)
(FMP)
(DX-)
(DX+)
(SD)
(X1)
(FWD)
(REV)
(CM)
(X8)
<
Y5C
>
<
Y5A
>
<
Y4
>
<
Y3
>
<
Y2
>
<
Y1
>
<
CME
>
(X7)
(X6)
(X5)
(X4)
(X3)
(X2)
0V
0V
+10Vdc
+24Vdc
+0
〜
10Vdc
[13]
[12]
[11]
[C1]
[FMA]
P(+)
Power supply ( *1)
3-phase
200 to 230V
50/60Hz
or
3-phase
400 to 480V
50/60Hz
Main circuit
Grounding
(*6)
Control circuit
Digital input
RS-485
Pulse output
Motor
Transistor output
Relay output
(*1) Use the inverter whose rated input voltage
matches the power supply voltage.
DBR(*7)
(*6)
NOTE: Common terminals [11], (CM), and <CME> for
control circuits are isolated from one another.
SR
3
2
1
(+)
(–)
60Hz
(pulse counter) (*2)
Digital frequency meter
FM (*2)
0 to 60Hz
Analog frequency meter
4 to 20mAdc
Current input
It is possible to input voltage
signals (0 to +10Vdc or 0 to
+5Vdc) to terminals [12]-[11]
instead of the potentiometer.
0 to 10Vdc
Voltage input
Potentiometer
power supply (*2)
Analog input
73
DC REACTOR (DCR)
(*2) (*4)
(*3) Use this peripheral device when necessary.
(*2) An optional device. Use it when necessary.
DB
DB
P
G
(*5) A built-in braking resistor (DBR)(*7) is
connected to the inverter before shipping.
When connecting an optional external braking
resistor (DB), remove the DBR connection
cables from [P(+)] and [DB]. The end of
removed cables (indicated with an X)
must be insulated.
(*4) When connecting a DC REACTOR (DCR),
remove the jumper wire (*6) that connects
the terminals [P1] and [P(+)].
(*6) Terminal for grounding the motor.
Connect it, if necessary.
External braking resistor (DB) (*2) (*5)
(CM)
(THR)
Alrarm output (for any fault)
(PLC)
1
2
30A
30B
30C
30
M C C B
or
G F C I
MC
(*3)
(*3)
Chapter01J(P19˜32).p65
07.8.9, 11:53
Page 29
Adobe PageMaker 6.5J/PPC
Содержание FRENIC5000G11S Series
Страница 1: ......
Страница 2: ......
Страница 154: ...3 30 3 12 13 P23 30 65p 07 8 9 12 34 Page 30 Adobe PageMaker 6 5J PPC...
Страница 166: ...4 12...
Страница 182: ...3 12 13 P23 30 65p 07 8 9 12 34 Page 30 Adobe PageMaker 6 5J PPC 5 16...
Страница 212: ...3 12 13 P23 30 65p 07 8 9 12 34 Page 30 Adobe PageMaker 6 5J PPC 6 30...
Страница 234: ...MEMO Chapter8 4 P15 p65 07 8 9 12 57 Page 18 Adobe PageMaker 6 5J PPC...
Страница 235: ......
Страница 236: ......