2-2
System Configuration (Product Overview)
2
DR-ID1270 Operation Manual 897N120821E
2.1.2 Features of the DR-ID1270
This section describes the main features of the DR-ID1270.
1 Light-weight, thin and roundish design of the flat panel sensor facilitates lifting and
enhances operability, for example, when it is set under a patient lying on a bed.
2 By utilizing FUJIFILM’s proprietary ISS (Irradiation Side Sampling) method, vapor
deposition technique of CsI scintillator, particle blend technique of GOS scintillator, and also
noise reduction IC, images with high sensitivity and high sharpness are obtained even in
low-density areas.
3 After an X-ray irradiation process is completed, the exposed image appears on the monitor
of the image processing unit in about one second at the shortest. In addition, since images
are compressed with our unique compression technology (CIP) during communication,
exposures can be made efficiently at short intervals.
4 The flat panel sensor has sleep mode. This power-saving design almost eliminates the
need of replacing the battery pack. In addition, since a removable battery pack is adopted,
it can be replaced even if the battery runs down.
5 The optional battery charger assist smooth exposure operations. The system can be used
even in an emergency since only 3 minutes of charge time are required to make about 30
exposures.
6 Extended Image Readout enables a long exposure for up to ten seconds (except for DR-
ID1275SE).
7 Since the external dimensions and thickness of the flat panel sensor are the same as those
of existing cassette for general exposure (compliant with ISO 4090), the flat panel sensor
can be loaded onto the exposure stand that has been used. In addition, since operation on
battery power and wireless communication are available, one flat panel sensor can be used
for multiple devices such as upright type and supine-position type radiography devices.
8 The flat panel sensor has the X-ray automatic detection function (SmartSwitch).
With this function, the flat panel sensor detects even a small amount of X-ray precisely to
start an exposure without connecting it to the X-ray device.
9 The flat panel sensors can be used in the 2.4GHz and 5GHz frequency bands. They can
also be used outdoors. * Use them in the appropriate frequency band according to the radio
law of each country.
10
By using a notebook computer as the image processing unit, and also by using the optional
FUJIFILM access point together with the image processing unit, the combination can be used
as a mobile system for rounds, since the need of carrying cables is eliminated. In addition,
exposures can also be made outdoors depending on the frequency band of radio wave.
11 Up to 100 flat panel sensors can be registered. Among the registered flat panel sensors, up
to five flat panel sensors can be used.
12 Since the flat panel sensor can be shared with multiple systems, the number of flat panel
sensors can be optimized.
13 As the flat panel sensors do not require calibration by the user, an exposure procedure can
be started immediately without complex processes.
Содержание FDR ES DR-ID1270
Страница 2: ...ii DR ID1270 Operation Manual 897N120821E...
Страница 28: ...1 22 For Safe Operation 1 DR ID1270 Operation Manual 897N120821E...
Страница 42: ...2 14 System Configuration Product Overview 2 DR ID1270 Operation Manual 897N120821E...
Страница 54: ...3 12 Basic Operation 3 DR ID1270 Operation Manual 897N120821E...
Страница 56: ...4 2 Daily Inspection and Maintenance 4 DR ID1270 Operation Manual 897N120821E...
Страница 68: ...Z 6 Appendix Z Precautions for Exposure DR ID1270 Operation Manual 897N120821E...
Страница 74: ...O 6 Appendix O Use of Optional Items DR ID1270 Operation Manual 897N120821E...
Страница 76: ...FUJIFILM MEDICAL SYSTEMS U S A INC 419 WEST AVENUE STAMFORD CT 06902 U S A...