3.1.6 Charging the Battery Pack for the Flat Panel Sensor
Charge the battery pack (optional) using the battery charger (optional).
CAUTIONS
Do not charge the battery pack other than those designated by FUJIFILM Corporation. If the
battery pack is charged under the charging conditions (voltage, current and charging method)
different from those specified by FUJIFILM Corporation, the battery pack may emit smoke,
ignite, explode or leak fluid.
CAUTIONS
When setting the battery pack into the battery charger, make sure that the orientation of the
battery pack is correct as shown in the figure in Step
1
. If the battery pack is forcibly set in
the wrong orientation, both the battery pack and the battery charger may be damaged and emit
smoke, ignite, leak fluid or cause electric shock.
When the battery pack installed in the flat panel sensor is fully charged, it is possible to perform exposures for a
maximum of approximately 500 images. However, the number varies depending on the usage conditions.
The capacity of the battery pack is displayed on the battery pack level indicator of the flat panel sensor and on the
screen of the image processing unit.
When the remaining capacity of the battery pack of the flat panel sensor becomes less than approx. 10 minutes,
a pop-up window appears on the image processing unit display, and exposure cannot be performed. If this
happens, replace or charge the battery pack.
When the remaining capacity of the battery pack installed in the flat panel sensor becomes low, the battery pack
level indicator is lit in orange and exposures cannot be performed. If this happens, connect the SE cable to the flat
panel sensor to charge the battery pack.
1
Set the battery pack in the battery charger.
When the battery pack is set, a buzzer sound is
generated and the charge status indicator LED
lights.
Two battery packs can be charged at the same time.
2
When battery charge is completed, remove
the battery pack.
When battery charge is completed, the charge status
indicator LED changes from blinking to lighting.
Содержание FDR ES DR-ID1270
Страница 2: ...ii DR ID1270 Operation Manual 897N120821E...
Страница 28: ...1 22 For Safe Operation 1 DR ID1270 Operation Manual 897N120821E...
Страница 42: ...2 14 System Configuration Product Overview 2 DR ID1270 Operation Manual 897N120821E...
Страница 54: ...3 12 Basic Operation 3 DR ID1270 Operation Manual 897N120821E...
Страница 56: ...4 2 Daily Inspection and Maintenance 4 DR ID1270 Operation Manual 897N120821E...
Страница 68: ...Z 6 Appendix Z Precautions for Exposure DR ID1270 Operation Manual 897N120821E...
Страница 74: ...O 6 Appendix O Use of Optional Items DR ID1270 Operation Manual 897N120821E...
Страница 76: ...FUJIFILM MEDICAL SYSTEMS U S A INC 419 WEST AVENUE STAMFORD CT 06902 U S A...