226
Current command value
a) reference current value for Q-Master values
b) current command value for operating the power source with constant welding current
in CC/CV mode
Unit
[A]
Range
min. - max.
Current decrease
With a standard arc, the current decrease parameter determines the speed at which the
short circuit current control changes to voltage control.
Unit
-
Range
0 - 65535
Current decrease when pulse ends
The parameter describes the linear decrease of the current when pulsing ends.
Unit
[A/ms]
Range
0 - 1000
Current guideline value
in MIG/MAG standard manual welding, the current guideline value is normally determined
by trial and error or by performing a test weld; it has no influence on the welding param-
eters
Unit
[A]
Range
0 - max.
Current-rise
With a standard arc, the current rise parameter determines the speed at which the weld-
ing current increases for the duration of the short circuit.
Unit
-
Range
0 - 65535
Current-rise when pulse begins
The characteristic parameter describes the linear increase of the current when pulsing
begins.
Unit
[A/ms]
Range
0 - 1000
Current-rise (short circuit)
The parameter describes how the current is ramped up in the case of a short circuit.
Unit
[A/ms]
Range
0 - 1000
Current-rise (tau)
time of transition from a linear slope to the pulse current
Unit
[ms]
Range
0 - 5
d_boostdown
for setting the linear current decrease rate following the boost phase for CMT character-
istics
Unit
[A/ms]
Range
0 - 1000
d_boostup
for setting the linear current rise rate at the start of the boost phase for CMT characteris-
tics
Unit
[A/ms]
Range
0 - 1000
Содержание RCU 5000i
Страница 2: ...2 ...
Страница 4: ...4 ...
Страница 151: ...151 EN Welding information screen for seam 2 section 1 The welding data of the respective section is displayed ...
Страница 154: ...154 Information Save complete screen Removing a memory card Save complete The memory card can now be removed 2 ...
Страница 200: ...200 Backup screen All data from the remote control unit are sa ved onto the memory card ...
Страница 202: ...202 Restore screen The last Data screen called up appears ...
Страница 207: ...207 EN Machine pre sets MIG MAG screen MIG MAG screen appears ...
Страница 210: ...210 Machine pre sets e g MIG MAG screen The last Data screen called up appears ...
Страница 242: ...242 ...
Страница 243: ...Appendix ...
Страница 244: ...244 Spare parts list RCU 5000i ...
Страница 245: ...245 ...
Страница 246: ...246 ...
Страница 247: ...247 ...