231
EN
Gen. Parameter control
for setting whether parameters will be entered internally or externally
Unit
-
Range
Internal/External
Ground current
characteristic parameters for setting the base current value, which is
maintained independently of the voltage
Unit
[A]
Range
min. - max.
Group number
various jobs are grouped together
Unit
-
Range
0 - 99
Guideline value for material
The guideline value for material strength is normally established by trial and error or by
means of a test weld; it has no influence on the welding parameters
Unit
[mm]
Range
0 - max.
Hot-current time Hti
for setting the length of time the HotStart current is active
(Hti)
Unit
[s]
Range
0 - 2
HotStart
A
rc
L
ength
S
tart - for setting an increased arc length for welding start-
up, for MIG/MAG synergic welding, standard welding process.
ALS
Unit
[%]
Range
0 - 100
HotStart current HCU
HotStart current - for setting the HotStart current for MMA welding
(e.g. for improved ignition properties)
(HCU)
Unit
[%]
Range
0 - 100
HotStart pulse cycles
for setting the HotStart pulse cycles in the case of CMT characteristic C0875
Unit
-
Range
-5.0 - +5.0
HotStart time (a)
A
rc
L
ength
t
ime - for preliminary setting of the time, during which for
MIG/MAG Synergic welding, standard welding process, the increased
arc length will be continually reduced to the currently set value of the
arc length.
ALt
Unit
[s]
Range
Off/0.05 -5.00
HotStart time (b)
for setting the value for the HotStart time in the case of CMT charac-
teristics C0873, C0876 and C0877
ALt
Unit
-
Range
-5.0 - +5.0
Содержание RCU 5000i
Страница 2: ...2 ...
Страница 4: ...4 ...
Страница 151: ...151 EN Welding information screen for seam 2 section 1 The welding data of the respective section is displayed ...
Страница 154: ...154 Information Save complete screen Removing a memory card Save complete The memory card can now be removed 2 ...
Страница 200: ...200 Backup screen All data from the remote control unit are sa ved onto the memory card ...
Страница 202: ...202 Restore screen The last Data screen called up appears ...
Страница 207: ...207 EN Machine pre sets MIG MAG screen MIG MAG screen appears ...
Страница 210: ...210 Machine pre sets e g MIG MAG screen The last Data screen called up appears ...
Страница 242: ...242 ...
Страница 243: ...Appendix ...
Страница 244: ...244 Spare parts list RCU 5000i ...
Страница 245: ...245 ...
Страница 246: ...246 ...
Страница 247: ...247 ...