163
EN
Selective exter-
nal/internal
switching of se-
lected parameters
with external pa-
rameter control
With external parameter control, the user can select and switch between external/internal
for selected parameters using F5 "Int/Ext". The external parameters can therefore be al-
tered and set internally on the remote control unit.
The function key F5 "Int/Ext" is available in the following menu items:
-
MIG/MAG synergic welding
-
MIG/MAG standard manual welding
-
MMA welding
-
TIG welding
-
Job welding
-
Optimizing & managing jobs
Example of external parameter entry: continuous
black bar - arc length correction selected
With external parameter control, call
up the parameters to be altered:
–
call up the relevant menu item
–
select corresponding "Data"
screen by pressing the right arrow
key (8)
–
select the parameter to be altered
using down (6) or up (7) keys
–
The parameter is displayed with a
continuous black bar.
Press F5 "Int/Ext":
–
The selected parameter is conver-
ted to internal parameter control
(black bar with "window")
Example of internal parameter entry: black bar with
"window" - arc length correction selected
Use the adjusting dial (18) to alter the
parameter value
1
2
3
IMPORTANT!
In robot welding, the F5 function key "Int/Ext" is disabled for safety reasons
if the parameter "Trigger mode" is selected in the "MIG/MAG synergic welding" menu item,
"Working parameters" screen.
F5 "Int/Ext" is greyed out:
Содержание RCU 5000i
Страница 2: ...2 ...
Страница 4: ...4 ...
Страница 151: ...151 EN Welding information screen for seam 2 section 1 The welding data of the respective section is displayed ...
Страница 154: ...154 Information Save complete screen Removing a memory card Save complete The memory card can now be removed 2 ...
Страница 200: ...200 Backup screen All data from the remote control unit are sa ved onto the memory card ...
Страница 202: ...202 Restore screen The last Data screen called up appears ...
Страница 207: ...207 EN Machine pre sets MIG MAG screen MIG MAG screen appears ...
Страница 210: ...210 Machine pre sets e g MIG MAG screen The last Data screen called up appears ...
Страница 242: ...242 ...
Страница 243: ...Appendix ...
Страница 244: ...244 Spare parts list RCU 5000i ...
Страница 245: ...245 ...
Страница 246: ...246 ...
Страница 247: ...247 ...