Sealant
till half way
Page 27
Service Manual STG5/7 intelligent STW5/7 intelligent form 9123999 rev. 05/2010
REMOVAL AND REPLACEMENT OF PARTS STW
Remove the right side panel and the knob
1.
and the thermometer display according
to prior procedures.
Remove the 2 screws that secure the main
2.
switch.
Remove the 2 nuts on the backside of the
3.
operating panel.
Use a stanley knife or any other long
4.
bladed knife to loosen the sealant
between the front panel, on the left side,
and the machine frame. Also loosen the
sealant on the bottom side from the left
to half way of the panel.
Lift the operating panel slightly and turn
5.
the outside of the panel towards the
inside of the machine (to break the seal-
ant).
Reverse the procedure to install.
6.
Note:
When reversing the procedure do not
forget to apply sealant again over the total
height of the panel and half way on the
bottom side. The Fri-Jado partnumber for
this sealant is 4302375 (Dow Corning 732).
GLASS OPERATION PANEL WITh BACkPLATE