Service Manual STG5/7 intelligent STW5/7 intelligent form 9123999 rev. 05/2010
REMOVAL AND REPLACEMENT OF PARTS STW
WARNING:
Disconnect the electrical power to the machine at
the main circuit box. Place a tag on the circuit box indicating
the circuit is being serviced.
Remove the right side panel according to
1.
prior procedure.
Remove the racks and bottom plate.
2.
Remove the cap nuts that secure the fan
3.
plate and remove fan plate.
Remove the wing nut on the fan blade
4.
and remove fan blade. Left handed
threads.
Disconnect wiring of the motor.
5.
Remove the screws that secure the motor
6.
and remove the motor.
Reverse the procedure to install.
7.
Note:
The blowers are equipped with a
capacitor. Check the direction of rotation of
the motor (clockwise, seen from inside) and
change the wiring if necessary.
Remove the right side panel and the fan
1.
plate according to prior procedure.
Remove the thermometer probe from
2.
the clamp inside the cavity and guide it
outside through the opening.
Remove the nuts that secure the ther-
3.
mometer and remove the thermometer
with clamping plates.
Reverse the procedure to install. Be sure
4.
to remove the protection paper from the
battery.
Note:
When there is no indication on the
display of the thermometer, the battery
could be empty and has to be replaced.
BLOWER MOTOR
ThERMOMETER
REMOVAL AnD REPLACEMEnT OF PARTS FOR THE STW5 AnD STW7