Page 24
Service Manual STG5/7 intelligent STW5/7 intelligent form 9123999 rev. 05/2010
REMOVAL AND REPLACEMENT OF PARTS STG
Remove the left side panel according to
1.
prior procedure.
Loosen the nuts of the upper hinge. The
2.
door must be closed.
Loosen the locknut and adjust the bolt in
3.
or out to adjust the door.
Tighten the nuts of the hinge and mount
4.
the left-hand panel.
Lift the door upward out of the hinges
1.
and place the door on a table.
Remove the cap nuts and rings on the
2.
profiles of the door.
Remove the profiles from the glass.
3.
Mount the profiles on the new glass. Do
4.
not forget the teflon rings of 2 mm inside
the holes.
Mount the cap nuts and rings.
5.
Place the door in the hinges.
6.
Note
: Tightening of nuts max. 4.2 nm.
DOOR ADjUSTMENT (LEfT SIDE)
DOOR GLASS INSIDE