Operation and Maintenance Manual
OnyX Pride Recuperators February 2019
Frapol Sp. z o.o. reserves the right to introduce changes without any prior notice.
Page
15
•
The electrical system of which the controller is part should be protected with a fuse matching the occurring loads.
•
Under no circumstances should the design of the controller be modified. It is forbidden to use the device, if it is
faulty or has been repaired by an unauthorized service centre.
•
Cables of the 230V supply network shall be routed in such a manner that they are not in contact with cables running
from low-voltage components.
•
Cables shall not come into contact with surfaces, which exceed their nominal operating temperature.
5.6.2
Installation
instructions
•
The control panel should be installed by a trained installer.
•
The control panel is designed for wall mounting, indoors.
•
The panel should be mounted at a height that ensures convenient operation, which is usually 1.5m above the floor.
•
To connect the control panel, use the original YTKSYekw 2x2x0.8 cable with one-sided earthed shielding. A
standard cable is 15m long, while all other length sizes are available on request. Communication is ensured over
distances of up to 100m from the device, without any additional surge protections and signal amplification.
•
The cable may be recessed in the wall or run along its surface.
•
Do not run and avoid any crossing of the cable with power supply cables in the building. The cable must not be
routed in the vicinity of any equipment that emits strong electromagnetic fields.
•
Do not use it in an environment, in which vapour condensation is present, and do not expose it to water.
•
To reduce any interferences during temperature measurement carried out by the unit, avoid areas with strong
sunlight, poor air circulation, close to heating appliances, or directly by doors and windows.
CAUTION!
The
panel
and
the
controller
can
only
be
installed
by
the
manufacturer
of
air
handling
units,
or
an
installer
familiar
with
this
manual.
The
assembly
should
be
carried
out,
according
to
the
binding
regulations,
standards,
and
guidelines
specified
in
the
controller
documentation.
CAUTION!
Only
the
original
shielded
cable
ensures
correct
operation
of
the
unit.
Cable
extensions
and
any
tampering
with
electrical
connections
are
not
permitted
and
may
void
the
warranty.
5.6.3
Assembly
The control panel and room panels should be installed, according to the following guidelines.
•
Drill holes (spacing of 90x43mm) in the wall and install screws, or cut a rectangular mounting hole.