Operation and Maintenance Manual
OnyX Pride Recuperators February 2019
Frapol Sp. z o.o. reserves the right to introduce changes without any prior notice.
Page
10
3.6
Efficiency
of
the
heat
recovery
system
and
electric
power
consumption
The temperature efficiency of heat recovery in the OnyX series recuperators was determined on the basis of laboratory tests
under the following operating conditions:
- temperature efficiency uoc 1
Fresh air parameters 7°C, 50%
Exhaust air parameters 20°C, 40%
- temperature efficiency uoc 2
Fresh air parameters 0°C, 50%
Exhaust air parameters 20°C, 40%
Normal operation mode (anti-freeze system inactive), with balanced, regulated ventilation system (fresh air volume =
exhaust air volume) and clean air filters. The electrical power consumption is determined for the external static pressure of
100 Pa.
CAUTION!
The
manufacturer
is
not
responsible
for
reduced
efficiency
of
heat
recovery,
resulting
from
improper
operation
and
imbalance
of
the
ventilation
system.
3.6.1
OnyX
Pride
400
Strumień powietrza [m3/h]
Air flow [m3/h]
Sprawność temperaturowa
Temperature efficiency
3.7
Technical
Data
3.7.1
OnyX
Pride
400
Air output (100Pa)
m
3
/h
470
Power consumption in fans
W
198
Pre-heater power
W
1000
Rated supply voltage
230V AC/50Hz
Type of fuse
-
nadprądowy, wył. instalacyjny C10
Dimensions (width x height x length)
mm
590 x 965 x 650
Dimensions of ventilation connections (diameter)
mm
160
Weight
kg
64
Class of filters used
-
G4
Machine dimensions (W x H)
mm
400 x 180
Protection class
-
IP 40
0
50
100
150
200
250
70,0
80,0
90,0
100,0
0
100
200
300
400
500
600
pobó
r m
oc
y
[W]
sp
ra
w
no
ść
tem
pe
rat
ur
pw
a
uo
c
[%]
strumie
ń
powietrza [m3/h]
sprawno
ść
temperaturowa uoc 1
sprawno
ść
temperaturowa uoc 2
pobór mocy