![Franklin Fueling Systems TS-SCM Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/franklin-fueling-systems/ts-scm/ts-scm_installation-manual_2328977020.webp)
16
TS-SCM STATUS AND CONTROL SCREENS
The status of each containment channel can be viewed at any time by navigating to the TS-SCM Status
or Control screens. To get to the TS-SCM Status or Control screens, go to TS-SCM>Status (Summary) or
TS-SCM> Control (Containment).
TS-SCM STATUS SUMMARY SCREEN EVO™ 550 AND EVO™ 5000
When viewing the TS-SCM Status Summary screen, remember to enable Auto Refresh. The Auto
Refresh button will allow the on-screen results to be automatically updated. When the results will update
is dependent on the user-defined parameter Refresh Rate found on the Configuration page.
STATUS AND ALARM INDICATORS
Indicator
Description
Fail to Hold Vacuum
The containment will not maintain the learned level of vacuum within the learned amount
of time.
Fail to Reach Vacuum
The containment has not reached the learned level of vacuum within the learned amount
of time.
High Vacuum
The vacuum level of the containment has exceeded 9" Hg.
Low Vacuum
The vacuum level of the containment has dropped below 1.25" Hg.
Not Learned
The containment has not been learned.
Program Error
SCM has encountered an error.
Pump Request
SCM is attempting to cycle the pump on.
Pump Request Ignored The pump is being used by another application.
Sensor Malfunction
SCM has detected a failure of the TS-SCM vacuum sensor.
Solenoid Status
Indicates whether the normally closed TS-SCM solenoid is open or closed.
Status
Indicates the condition of the containment.
Vacuum Level
A direct reading from the TS-SCM vacuum sensor.
Vacuum Unstable
The level of vacuum in the containment is not statistically sound.
For more information on alarms and troubleshooting, refer to the "Alarms" chapter in this manual.