The AC Input Module can accept incoming dispenser hook control signals. Hook signals are used to
activate the STP via the relay channel connected to the pump controllers. Control signals from the
dispenser tell the console which product is requested by the dispenser, then control signals activate the
appropriate STP. To perform tests accordingly, the TS-SCM needs to know when pumps / dispensers are
being used by other applications.
Parameter
Parameter Value
Number Gasoline
Hooks per
Dispenser
The number of product hook signal inputs to the console from the dispensers.
Channels
Only select the total number of inputs intended for use.
Name
Should be a specific device from which the signal is originated.
Enabled
If yes, will allow the channel to be mapped to another module. Other modules
may use this signal to trigger an event.
Active State
If set to High, a high signal level will activate the channel and a low signal will
deactivate the channel. If set to Low, then the channel is inverted and will only
become active when a signal is absent and inactive when a signal is present.
Action
None (no response)
Alarm (to activate an Alarm)
Event (To trigger an event, i.e. record the event to the application)
Example: AC Input Module TS-SCM Setup
Group Name
Parameter Name
Parameter Value
AC Input Modules
Number Gasoline Hooks per
Dispenser
2
Module 1
Channels
‘#’
Channel 1
Name Disp 1 Unleaded Hook Signal
Enabled Yes
Active State High
Action None
Channel 2
Name Disp 2 Unleaded Hook Signal
Enabled Yes
Active State High
Action None
Channel 3
Name Disp 3 Unleaded Hook Signal
Enabled Yes
Active State High
Action None