Commissioning
3. Commissioning
Have the end user provide you with the operating manual of the automatic feeder, the separate
operating manuals of additional equipment to be connected as well as the safety data sheets
for the cleaning agents.
The appendix contains a checklist with all points you have to observe during commissioning or
recommissioning (see 10.1 "Checklist for commissioning and recommissioning" - 114).
3.1
Setting up the feeder
CAUTION!
Beware of the health hazards caused by lifting heavy loads.
The automatic feeder weighs approx. 85 kg.
►
Never carry the automatic feeder by yourself.
•
When setting up the automatic feeder, observe the occupational safety precautions.
•
Always set up the automatic feeder on an even surface.
Note:
Using its adjustable feet, if necessary, you can level the automatic feeder.
•
Set up the automatic feeder in a frost-free location. If this is not possible, inform the end user
that he/she must protect the automatic feeder from frost using additional equipment such as
the additional frost protection equipment or suction hose heating made by Förster-Technik.
•
Set up the automatic feeder in a location where the temperature cannot exceed 40°C and
the humidity cannot exceed 80%.
•
If the end user intends to operate the automatic feeder outside of closed spaces, inform the
user that he/she must protect the automatic feeder from rain and moisture, for example with
a roof.
•
Make sure that there is a drain where the automatic feeder is set up, for the cleaning water.
•
Be sure to comply if necessary with the manufacturer's instructions and national regulations
for the use, storage and place of installation of the cleaning agent being used.
•
Inform the user that the automatic feeder and its cables must be protected from exposure to
sunlight.
•
In order to ensure correct operation of the calibration scales, remove the wing nut fitted for
transport restraint on the left side of the mixer.
•
Remove the calibration beaker (optional) from the mixer beaker.
•
Cut the discharge hose to length. Keep it as short as possible.
A discharge hose has a length of 50 cm and may not be either extended or constricted.
NOTICE!
►
Ensure that the discharge hose is laid so as to be free of kinks or loops, as these can dam-
age it.
•
Inform the user that he must not extend the discharge hose.