112
Faults and warnings
•
How often the automatic feeder received no response from the
identification
system.
•
How often the minimum temperature in the heat exchanger was not met (
heating
).
•
How often the water test was negative (
water shortage
).
•
How often the mixer could not be drained via the mixer drain valve (
mixer draining
).
•
How often the
heating
function was faulty.
•
How often erroneous values were provided by the
water meter
.
•
How often faults occurred during automatic flushing of the mixer (
Flushing
).
•
How often the test of the boiler was run unsuccessfully (
boiler not filled
).
•
How often implausible values were reported by the temperature sensors in
Boiler
and
Mix-
er
.
•
How often the
temperature
of the boiler water was
too high
. e.g., if the automatic feeder
was supplied with hot water.
•
How often the
supply electrode
was grounded before mixing a feeding portion.
•
How often a CAN node is registered with the incorrect CAN address (
incorrect ID
).
•
How often the automatic feeder could not switch to automatic mode because, for example,
the liquid and powder feed components were not calibrated (
calibration
).
•
How often the same address has been assigned in the CAN bus to devices (
duplicate ad-
dress
).
•
How often a fault has occurred in connection with the
ID chip
.
•
How often
Unknown transmitter
was detected by the identification system.
•
How often it has been indicated that an animal number has already been assigned (
dupli-
cate animal no.
).
•
How often the
flushing agent
empty indicator was displayed.
•
How often the automatic feeder tried to establish a connection to the cloud (
Cloud connect
retry/Cloud reconnect
)
You check the faults as follows:
1. Navigate via
> Diagnostics
to switch to the
Checking
sub-menu.
2. Select the fault that occurred.
2.1.
In
Number
, you check how many times the fault occurred.
2.2.
In
since
, you check when the entries were last deleted.
2.3.
In
last on
or
last at
you can determine the day on which or the time at which a certain
event last occurred.
3. Confirm
Delete?
by choosing
to delete the fault message.