Setup
3. Confirm your entry with
.
5.5.9
Air valve
The air valve is part of the compressed air cleaning system.
5.5.10
Mixer temperature sensor
The temperature sensor in the mixer continually records the temperature of the feed in the mixer
beaker. If the temperature deviates from the set value, the boiler heater is adjusted to compen-
sate. The feed always has the desired temperature, regardless of the season. The temperature
sensor is included as standard.
You activate the mixer temperature sensor in the mixer as follows:
1. In the setup menu, open the
Equipment
menu item.
2. In
Mix. Sensor T.
, choose
yes
if there is a temperature sensor fitted, otherwise choose
no
.
3. Confirm your entry with
.
5.5.11
Water meter
Please do not change the factory settings [
yes
].
5.5.12
Supply and point electrode
You activate the electrodes as follows:
1. In the setup menu, open the
Equipment
menu item.
2. In the
Elec. Supply
menu, select [
no
] and in the
Elec. Point
menu, select [
yes
].
3. Confirm your entry with
.
5.6
Identification
Here you set the identification system:
The input or reading sensitivity of the identification system is set via the squelch value. The larg-
er the entered value, the lower the range of the identification (see 3.6 "Connecting the anten-
nas" - 26).
You set the identification system as follows:
1. In the setup menu, open the
Identification
option.
2. In the
Type
menu, select the identification system
Multi, Tiris
or
Ned
.
3. In
Squelch
, select the squelch value.
4. Confirm your entry with
.