Faults and warnings
101
3. Assign another address which is still available to the CAN node with the duplicate address.
For more information on assigning CAN addresses, see the
Setup > Address
chapter (see
5.4.3 "Automatic feeder address" - 63).
Note:
If possible, use an address from the standard range of numbers for the CAN partici-
pant concerned.
4. Confirm the changes with
.
5. To exit setup, repeatedly press
, until the message
End setup?
appears. Confirm with
.
6. Delete the warning on all feeders.
9.2.6
Unknown transmitter
The
Unknown transmitter warning
appears in your display:
•
If a transmitter is detected by the identification unit for which no animal number has been
assigned.
•
If a transmitter number has been allocated to an animal number, but has still not been reg-
istered.
You rectify the warning as follows:
1. Confirm
Unknown transmitters warning
by choosing
.
2. In
No.
, check the unknown transmitter number.
3. In
Number
, you check how often the unknown transmitter number has been identified.
4. In
Time
, you check when the transmitter was last registered by the identification system.
5. Confirm
Delete?
by choosing
, if you wish to delete the transmitter number.
6. Confirm
Register
by choosing
, if you want to allocate the unknown transmitter number
to an animal number.
9.2.7
Calibration
If the last calibration was 120 days ago or if automatic calibration failed, the
calibration warn-
ing
will appear in your display. You will see which components you have to calibrate.
You rectify the warning as follows:
1. Calibrate all components shown in the display (see 3.23 "Calibrating feed components" -
2. Confirm
delete warning?
by choosing
.
Note:
If you delete the warning without calibrating, the message will appear again the next day.
Содержание TAP5-VS2-50
Страница 121: ...Appendix 121 10 4 Standard feeding plans ...
Страница 122: ...122 Appendix ...
Страница 129: ...Index 129 Unknown transmitter 101 Water connection 12 Water pressure 24 Weight 12 ...