Faults and warnings
99
9.2
Warnings
9.2.1
Emptying the mixer
If the mixer cannot be emptied, the message
Warning, draining the mixer
will appear. For ex-
ample, this can be because the drain is clogged or the feeding pump is no longer running.
DANGER!
Fatal electric shock.
The electrical components of the automatic feeder are live.
►
Always switch off the automatic feeder firstly with the Main switch and then disconnect the
power plug before working on components of the feeder.
You rectify the warning as follows:
1. Check all components carrying feed from the mixer to the mixer drain valve or from the mixer
up to the teat for clogs and remove them.
NOTICE!
The hose which goes from the mixer drain valve to the drain channel must not be length-
ened.
2. Check the feeding pump.
2.1.
Confirm
Mixer draining warning
by choosing
.
2.2.
Confirm
Feeding pump: start?
by choosing
.
The feeding pump will be actuated.
3. Check the mixer drain valve.
3.1.
Confirm
Mixer draining warning
by choosing
.
3.2.
Confirm
Mixer drain: open?
by choosing
.
The mixer will be drained.
4. Check the rod electrode.
4.1.
Visually check the rod electrode for deposits.
4.2.
Check that the rod electrode works properly (see 9.5.3 "Checking sensors" - 110).
5. Fill and drain the mixer.
5.1.
Confirm
Bo. water start?
by choosing
.
The mixer will fill up with water.
5.2.
Confirm
Mixer: draining?
by choosing
.
The mixer will be drained.
If the fault has been fixed, acknowledge the message
Delete warning?
in the display with
.
Содержание TAP5-VS2-50
Страница 121: ...Appendix 121 10 4 Standard feeding plans ...
Страница 122: ...122 Appendix ...
Страница 129: ...Index 129 Unknown transmitter 101 Water connection 12 Water pressure 24 Weight 12 ...