Faults and warnings
109
9.5.1.2
Motors
Check the motors as follows:
1. Navigate via
> Diagnostics
to switch to the
Motors
sub-menu.
2. Confirm
Mixer: start?
by choosing
, to start the mixer.
3. Confirm
Powder start?
by choosing
, to start the powder conveyor.
4. In the
flushing agent 1
menu, press
.
4.1.
Confirm
check?
by choosing
, to check the cleaning agent pump.
4.2.
Confirm
Flushing agent: start?
by choosing
, to start the cleaning agent pump.
Check that cleaning agent flows from the outlet.
5. In the
start flushing agent 2?
menu, press
.
5.1.
Confirm
check?
by choosing
, to check the cleaning agent pump.
5.2.
Confirm
Flushing agent: start?
by choosing
, to start the cleaning agent pump.
Check that cleaning agent flows from the outlet.
WARNING!
Hazardous or irritant materials!
►
Collect the cleaning agent residues and additive residues and dispose of them safely. When
doing this be sure to comply with the manufacturer's instructions and national regulations for
the use and disposal of the cleaning agent and additive being used. In addition a mixer
cleaning must then be performed.
6. Confirm
Feeding pump: start?
by choosing
, to start the feeding pump.
9.5.2
Checking the heating
In this menu, you check the boiler heating system.
Check the boiler heating system as follows:
1. Navigate via
> Diagnostics
to switch to the
Heating system
sub-menu.
2. Confirm
switch on?
by choosing
.
3. In the
Boiler
menu, you check the temperature.
4. Keep the
in
switch on?
Depressed, the boiler will then heat up. If the temperature rises,
that means the heater is working.