6.2 OUTER TERMINAL BOX ELECTRICAL CONNECTIONS
All the electrical connections are made via the terminal box situated on the back of the
control panel.
The additional boards (used to control the zones or complex panel solar systems) are
housed is an external casing on the back of the control panel:
Additional
board
Additional
board
Electrical
connections
Legend:
1-2
ambient thermostat 2
3-4
ambient thermostat 1 or remote control
5-6
external probe
7-8
sonda bollitore caldaia SBC per versione KR
(10K Ohm a 25°C B3435 L” 3m)
9-10
solar tank heater probe (SBS)
11-12
solar collector probe (SCS)
13-14
timer o termostato boiler solo per versione KR
15-16
valvola motorizzata a ritorno a molla (P28=0) o pompa sanitaria (P28=1) solo
per versione KR
17
GND serial connection
18
485A serial connection
19
485B serial connection
20
+5V serial connection
21
relay normally-open phase (NO)
22
relay normally-closed phase (NC)
23
multifunction relay neutral
Important. F
or complex solar panel systems, the solar valve probe (SVS) must be
connected to the additional board.