________________________________________________________________________________
7
AST 14 C 257/00
1.3 TECHNICAL DATA
General Features
KC-KR 24 KC-KR 28 KC-KR 32
Operating parameters
Category
II2H3P
Burner nozzles
no.
2
Minimum CH circuit flow rate
l/h
400
600
Maximum and minimum CH pressure
bar
3-0.5
Maximum and minimum DHW circuit pressure
bar
6-0.5
DHW specific flow rate û t 30°C
l/min
13.5
15.5
16.2
Double flow probe intervention temperature OFF
°C
105
Double flow probe intervention temperature ON
°C
90
Flue gas thermostat intervention temperature
°C
105
Standard heating regulation range
°C
20-78
Maximum standard operating temperature
°C
78+5
Reduced heating regulation range
°C
20-45
Maximum reduced operating temperature
°C
45+2
DHW regulation range
°C
35-57
Maximum DHW operating temperature
°C
57+5
Nominal expansion vessel capacity
l
10
Maximum recommended system capacity (**)
l
200
Nominal ratings
Power Supply: Voltage / Frequency
V – Hz
230-50
Mains supply fuse
A
2
Electrical cabinet protection
IP
X5D
Max. input power
W
121
Input power on standby
W
2.4
Overall dimensions and connections
Height
mm
750
Width
mm
420
Depth
mm
315
Gas connection
-
G ½
Flow and return connection
-
G ¾
Cold water and DHW/tank heater connection
-
G ½
Net weight
kg
30.5
32
38
Consumption
Natural gas consumption (*) m
3
/h 2.51 2.80 3.22
Propane gas consumption (*)
kg/h
1.84
2.05
2.36
Operating features
Type of ignition
-
Electronic
Flame surveillance
-
Ionisation
Type of detection
-
No phase-neutral polarisation
DHW production
-
Instantaneous
(*) Value related to 15°C-1013 mbar
(**) Maximum water temperature at 83°C with vessel preloaded at 1 bar