________________________________________________________________________________
85
AST 14 C 257/00
7.4 Ø 60 SPLIT VENT DUCT
Maximum pipe length
Type of installation: B23 - B53*
TYPE OF
INSTALLATION
PIPE
MATERIAL
KC 24
KR 24
KC 28
KR 28
KC 32
KR 32
Air
intake
Flue gas
vent
Max L [m] Max L [m] Max L [m]
B23; B53
----
polypropylene
23
23
20
* The minimum discharge pipe length must be one metre
Table of load losses in Ø 60 ducts
Part
Vent
[m]
Intake
[m]
24 kW
28 kW
32 kW
24 kW
28 kW
32 kW
Wall vent terminal
4.5
-
1m extension
1
1
0.5m extension
0.5
0.5
90° elbow
1
1
45° elbow
0.5
0.5
60mm tee with condensate drain
0.5
1
-
60mm tee
0.5
1
1