________________________________________________________________________________
25
AST 14 C 257/00
Inside the module, the return pipe is in the coldest zone (condensing chamber) to ensure
flue gas condensing and water pre-heating so that the water temperature is higher when
flowing into the combustion chamber. This decreases fuel consumption and prevents the
formation of condensate, which would drip onto the burner and damage it.
After passing through the elements in the combustion chamber, the flue gases pass
through the condensing chamber, where a portion of them starts to condense, if allowed
by the return temperature, and the combustion residues flow out of the hood.