________________________________________________________________________________
10
AST 14 C 257/00
SECTION 2
TOUCH-SCREEN CONTROL PANEL AND DIAGNOSTICS
2.1 USER INTERFACE
1. LCD
The LCD shows the boiler status and operating details (see
below).
2. DHW tem perature setting
This button is used to regulate (increase or decrease) the DHW
temperature, within a range of 35°C to 57°C.
3. Boiler resetting
Press this button to resume boiler operation after a shutdown (only with resettable failures), or return to the
home page when selecting the parameters.
4. Request for inform ation and param eter confirm ation
Press this button to scroll through some display-only parameters in sequence, and to confirm the settings of
the modified parameters.
5. Boiler operating m ode selection
Press this button to set one of the following functions:
SUMMER
: Boiler on DHW only.
WINTER
: Boiler on both CH and DHW.
CENTRAL HEATING ONLY
: Boiler on CH mode only.
STANDBY OFF: boiler in standby: CH and DHW functions disabled.
6. Heating w ater tem perature regulation
This button is used to regulate the water temperature in the CH system from 20°C to 45°C (reduced range)
or 78°C (standard range). With an external probe however, the fictitious temperature can be regulated (refer
to the temperature regulation section).
1
2
3
4
5
6
Im portant: Touch the button area to access the various
settings. This activates backlighting (keys + LCD) and
access to the various functions. To guide the user, only
active buttons are backlit.
One minute after the last button has been touched, the
interface is disabled and the light sw itches off.
N.B. Backlighting has three separate settings (parameter
P78): 0 = standard, 1 = LCD alw ays ON, 2 = LCD +
buttons alw ays ON (default P78=0):