________________________________________________________________________________
31
AST 14 C 257/00
AIR/GAS MIXER
The air/gas mixture is generated inside the mixer, thanks to air flow via the vacuum
developed by the fan, and sent to the gas valve mechanism.
When the fan is powered on, it creates a vacuum proportional to its speed, giving a
mixture with a constant ratio from maximum to minimum power. In addition to extracting
the combustion air, the fan impeller mixes the air and gas and conveys the mixture along a
pipe to the burner.
The mixer is connected to the fan suction inlet, and features a mechanism that increases
or decreases the air and gas flow rate according to the requested output, thereby ensuring
very low minimum boiler modulation. Inside the mixer is a double deflector, which at the
minimum power closes by gravity the gas outlet of one nozzle and cuts off half of the
combustion air flow. When fan power is increased, these deflectors are opened by
vacuum, allowing the passage of both air and gas.
Deflectors open
Deflectors closed
GAS
INLET
COMBUS TION
AIR
INLET
AIR/GAS
MIXTURE TO
BURNER