AST 14 C 257/00
Below is an overview of the different situations.
Output
Type of
request
Lim it w ater flow
rate
Burner ON
tim e
Burner OFF
tim e
Error
[ kW]
[l/h]
[min]
24 kW
Heating, anti-
freeze,
chimney-
sweep
367
3 1
min
E81
333
2 2
min
E82
300
1 3
min
E83
Plate DHW,
tank heater
367
3
5 sec
E81
333
2 E82
300
1 E83
28 kW
32 kW
Heating, anti-
freeze,
chimney-
sweep
550
3 1
min
E81
500
2 2
min
E82
450
1 3
min
E83
Plate DHW,
tank heater
550
3
5 sec
E81
500
2 E82
450
1 E83
The burner is completely switched off (0 min ON) if, in the worst case (300 or 450 l/h), the
flow and return temperature derivative values are below 0.5°C/seconds, in which case the
reference error is E84.
Important. Errors E81, 82, 83 and 84 are not displayed by default, on the boiler screen,
they are only recorded in the super-technical parameters memory (from P01 to P05).
During intervention of the water flow control and subsequent switching on and off of the
burner, the pump remains powered on.
Function chart of the 24 kW heat exchanger with ¨ t 35°C output
Boiler operation
with flow rate
control
Normal
operation
Zone E81
Zone E82
Zone E83
Zone E84
Allowed