9
2.
INSTRUCTIONS fOR THE USER
2.1.
Control panel
1
2
3
5
4
6
1. Set domestic hot water temperature
These buttons are used to set the domestic hot water temperature within a range from 35°C to 57°C.
2. Recall information and confirm parameters
This button is used to scroll the sequence of the values of some parameters, such as: primary flow water temperature, DHW temperature and
display of the last 5 shutdowns. This button is also used to confirm parameter settings.
3. Select boiler mode
Press this button to set the following functions.
SUMMER
Boiler only produces domestic hot water.
WINTER
Boiler provides central heating water and produces domestic hot water.
CENTRAL HEATING ONLY
The boiler provides central heating water only.
STANDBY
Boiler in standby mode: central heating function and DHW production disabled.
4. Boiler Reset function
This button resets the boiler operation after the burner shutdown device (lockout) has been activated.
5. LCD
The LCD displays the boiler status and operating data (see fig. 2).
6. Set central heating water temperature
These buttons are used to set the heating water temperature within a range from 20°C to 78°C.
7. Water pressure gauge
This shows the pressure of the water in the primary heating system.
7
fig. 1
Fondital is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic
heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance.
Benchmark is managed and promoted by the Heating and Hotwater Industry Council.
For more information visit www.centralheating.co.uk
Please ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions supplied
with the product and that you have signed it to say that you have received a full and clear explanation of its operation. The installer is legally
required to complete a commissioning checklist as a means of complying with the appropriate Building Regulations (England and Wales).
All installations must be notified to Local Area Building Control either directly or through a Competent Persons Scheme. A Building Regulations
Compliace Certificate will then be issued to the customer who should, on receipt, write the Notification Number on the Benchmark Checklist.
This product should be serviced regularly to optimise its safety, efficiency and performance. The service engineer should complete the relevant
Service Record on the Benchmark Checklist after each service.
The Benchmark Checklist may be required in the event of any warranty work and as supporting documentation relating to home improvements
in the optional documents section of the Home Information Pack.
8
Содержание Antea 24kW Range
Страница 39: ...39 A fig 21...
Страница 51: ...51 1 2 31 32 33 34 fig 31 9 Spare part list...
Страница 52: ...52 4 5 6 7 9 8 10 11 12 13 29 14 15 3 17 18 19 20 21 22 23 24 25 26 27 29 29 30 28 14 16 fig 32...
Страница 56: ...56...
Страница 57: ...57...
Страница 58: ...58 Affix your analyser print out here...
Страница 59: ...59...