Once the remote control has been installed, the boiler LCD will display the following code:
For instructions on how to connect the remote control, refer to par. 4.9. and the remote thermostat instruction booklet.
Only original remote controls supplied by the manufacturer must be used.
If non-original remote controls are used, correct operation of the boiler, or of the remote control, cannot be guaranteed.
2.5.
Boiler shutdown
The boiler locks out automatically if a malfunction occurs.
Refer to Tables 1 and 2 to identify the boiler operating mode.
To determine the possible causes of malfunction, see also paragraph
10
.
Table of fault codes
section
is at the end of this manual.
Below is a list of shutdowns and the procedure to follow for each.
2.5.1. Burner shutdown
Fault code E01 is displayed flashing on the LCD display in the event of burner shutdown due to no flame recognition.
If this happens, proceed as follows:
check that the gas cock is open and that gas is available at the appliance to check the gas supply by turning on another gas appliance and check
the emergency control valve is on;
- once you have confirmed fuel is available, press the reset button (4) (fig.1) to restore burner operation: if, after two starting attempts, the boiler
still fails to start and enters shutdown mode again, contact the fondital Helpline 01329 282555 or qualified personnel for maintenance.
If the burner shuts down frequently, there is a recurring malfunction, so contact a service Centre or a qualified service engineer.
2.5.2. Shutdown due to air intake/flue gas discharge system malfunction
If the air/flue gas system malfunctions, the boiler shuts down. The code E03 (flue gas thermostat activation) is displayed flashing on the LCD.
Should the above happen contact the Fondital helpline UK or CORGI registered engineer with appropriate competence for service.
2.5.3. Shutdown due to a water circulation malfunction
If there is a malfunction in water circulation in the heating system, the boiler shuts down.
The codes E81 or E82 or E83 or E84 are displayed, according to the malfunction.
Malfunction code
Water flow l/h
(mod. KC 24)
Water flow l/h
(mod. KC 24)
E81
367
550
E82
333
500
E83
300
450
E84*
300
450
*When code E84 is displayed both flow and return temperatures vary by 0.25 °C per second.
There can be 2 different situations:
a) the pressure gauge (7, fig. 1) shows a pressure lower than 1 bar
Proceed as follows to restore the correct water pressure:
- open the loading tap upstream the boiler to fill the system with water;
- keep the tap open until the pressure gauge shows a value of 1-1.3 bar.
- turn the tap off on completion.
- press the reset button (4 in fig. 1) to restore boiler operation then set it to the desired operating position.
If the boiler still fails to operate, contact the fondital helpline UK or CORGI registered engineer with appropriate competence for service.
Make sure you close the cock carefully after filling.
If you do not, when the pressure increases, the safety valve may activate and discharge water.
b) the pressure gauge (7, fig. 1) shows a pressure of 1-1.3 bar
Should the boiler shut down again, contact the fondital helpline UK 01329 828555 or a Gas Safe registered engineer with appropriate compe-
tence for service.
Содержание Antea 24kW Range
Страница 39: ...39 A fig 21...
Страница 51: ...51 1 2 31 32 33 34 fig 31 9 Spare part list...
Страница 52: ...52 4 5 6 7 9 8 10 11 12 13 29 14 15 3 17 18 19 20 21 22 23 24 25 26 27 29 29 30 28 14 16 fig 32...
Страница 56: ...56...
Страница 57: ...57...
Страница 58: ...58 Affix your analyser print out here...
Страница 59: ...59...