50
8.16.
Pressure relief valve
• Access behind the control panel as described in 7.2 and drain the boiler heating circuit
• Disconnect the pressure relief valve outlet pipe
• Extract the retaining clip and lift the valve out of the pump housing
• Replace with the new valve and reassemble in reverse order
• Refill and pressurize the system
8.17.
DHW heat exchanger (fig. 30)
• Access behind the front panel as described in 7.2 and drain both heating and DHW circuits
• Remove the condensate trap, as described in 8.20 to gain more space for extracting the heat exchanger
• Unscrew the two socket head capscrews holding the DHW heat exchanger with a 4 mm Allen key
• Rotate the heat exchanger counterclockwise and extract it from the lower part of the boiler. Be careful not to allow water to drip on any electrical
component
• Reassemble with a new heat exchanger in reverse order
• Refill and pressurise the system
8.18.
Three-way valve cartridge
• Access behind the control panel, as described in 7.2, and drain the heating circuit
• Remove the three way valve motor, as described in 8.8
• Unscrew the two screws holding the cartridge and remove it, taking care non to drip water onto any electrical component
• Insert the new cartridge in place and reassemble in reverse order
• Refill and pressurize the system
8.19.
Expansion vessel (fig. 28)
Note: check the pressure of the new vessel, which must be about 1 bar, before installing it. If necessary, pressurize it.
• Access the room sealed chamber, as described in 7.2, and drain the heating circuit
• Disconnect the pipe from the bottom of the expansion vessel
• Unscrew the two screws holding the top support bracket
• Extract the expansion vessel from the boiler and replace it
• Reassemble in reverse order
• Refill and pressurize the system
8.20.
Condensate trap (fig. 30)
• Access the room sealed chamber as described in 7.2
• Place a container under the boiler and remove the condensate trap cap, in order to empty the condensate trap
• Disconnect the top and drain connections of the condensate trap
• Unscrew the threaded washer holding the condensate trap to the bottom of the sealed chamber, and remove the condensate trap
• Fit the new trap and assemble in reverse order
Note: fill the new trap with water once installed and before operating the boiler
Содержание Antea 24kW Range
Страница 39: ...39 A fig 21...
Страница 51: ...51 1 2 31 32 33 34 fig 31 9 Spare part list...
Страница 52: ...52 4 5 6 7 9 8 10 11 12 13 29 14 15 3 17 18 19 20 21 22 23 24 25 26 27 29 29 30 28 14 16 fig 32...
Страница 56: ...56...
Страница 57: ...57...
Страница 58: ...58 Affix your analyser print out here...
Страница 59: ...59...