TECHNICAL fEATURES AND DIMENSIONS
3.1.
Technical features
The boiler is equipped with a fully pre-mixed gas burner. The following model is available:
- KC: condensing boiler with sealed chamber and forced draught, supplying CH water and for instant DHW production;
This version is available with two power ratings:
- KC 24:
with heat input of 24.9 kW
- KC 28:
with heat input of 27.9 kW
Both models are equipped with electronic ignition and ionisation flame sensing device.
The boilers meet local applicable Directives enforced in the country of destination, which are stated on their rating plate.
Installation in any other country may be a source of danger for people, animals and property.
The key technical features of the boilers are listed below:
Operating features
- CH electronic flame modulation with timer-controlled rising ramp (60
seconds)
- Electronic flame modulation in DHW mode
- DHW priority function
- CH flow anti-freeze function: ON 5°C; OFF 30°C or after 15 minutes of
operation if CH temperature > 5 °C
- DHW anti-freeze function: ON 5°C; OFF 10°C or after 15 minutes of
operation if DHW temperature > 5 °C
- Timer-controlled flue cleaning function (15 minutes)
- CH maximum heat output adjustment through parameter P7
- Ignition heat output adjustment through parameter P6
- Possibility to select the heating range through parameter P10:
standard or reduced
- Ignition flame propagation function
- CH thermostat timer adjustable through parameter P11: 4 minutes
- Heating pump post-circulation function in CH, ANTI-FREEZE and
FLUE CLEANING mode (30 seconds)
- DHW post-circulation function: 30 seconds
- Post-circulation function for heating temperature > 78°C (30 seconds)
- Post-ventilation function after working: 10 seconds
- Post-ventilation function for heating temperature > 95°C
- Pump and diverter valve anti-seize function: 30 seconds of operation
every 24 hours with boiler not in use
- Ready for connection to a room thermostat (optional)
- Ready for operation with an external probe (optional supplied by the
manufacturer, part number 0SONDAES01)
- Ready for operation with an OpenTherm remote control (optional,
supplied by the manufacturer)
- Ready for operation with a module for different temperature zones
- Anti- water hammer function: can be set from 0 to 3 seconds
through parameter P15
Manufacturing characteristics
- IPX4D electrically protected control panel
- Integrated, modulating electronic safety board
- Electronic ignition and ionisation flame detection device
- Stainless steel, fully pre-mixed burner
- Mono-thermal, high efficiency, composite and stainless steel heat
exchanger with air purging device
- Twin shutter modulating gas valve with constant air/gas ratio
- Modulating, electronically managed combustion fan
- Three-speed pump with air purging device
- Minimum pressure switch
- DHW and CH temperature probe
- Safety limit thermostat
- Flue gas thermostats
- Integrated, automatic by-pass
- 9 litre expansion vessel
- Stainless steel plate DHW heat exchanger
- Motorised diverter valve
- DHW priority flow switch
- 13 l/min DHW flow-restrictor (KC24), 14 l/min (KC28)
User interface
- Liquid crystal display showing the boiler operating status
- Mode button: OFF, WINTER, SUMMER and CENTRAL HEATING ONLY
- DHW water temperature regulator: 35-57°C
- CH water temperature regulator: 20-78°C (standard range) or 20-45
°C (reduced range)
- Heating water pressure gauge
Содержание Antea 24kW Range
Страница 39: ...39 A fig 21...
Страница 51: ...51 1 2 31 32 33 34 fig 31 9 Spare part list...
Страница 52: ...52 4 5 6 7 9 8 10 11 12 13 29 14 15 3 17 18 19 20 21 22 23 24 25 26 27 29 29 30 28 14 16 fig 32...
Страница 56: ...56...
Страница 57: ...57...
Страница 58: ...58 Affix your analyser print out here...
Страница 59: ...59...