55
BOILER STATUS
MALfUNCTION
PROBABLE CAUSE
SOLUTION
Fault code E06 shown on LCD
display.
Normal operation is restored
automatically when the faults
causing the alarm state are
rectified.
DHW probe is not working
DHW probe is disconnected
Reconnect it
DHW probe is faulty
Replace it
Fault code E15 shown on LCD
display.
Normal operation is restored
automatically when the faults
causing the alarm state are
rectified.
Return probe not working.
Return probe disconnected
Reconnect it
Return probe faulty
Replace it
Boiler is not supplying DHW
DHW flow switch is not working
System insufficient pressure or
flow rate.
Check DHW system
Check DHW flow switch filter
DHW flow switch probe is faulty or
disconnected
Replace or reconnect it
DHW flow switch is blocked
Replace it
Fault code E40 shown on LCD
display.
Normal operation is restored
automatically when the faults
causing the alarm state are
rectified.
Combustion fan not working.
Fan disconnected.
Reconnect it
Fan faulty.
Replace it
Fault code E31 shown on remote
control display.
Normal operation is restored
automatically when the faults
causing the shutdown state are
rectified.
No communication possible
with Remote Control
Connector cable between boiler
and remote control disconnected
Reconnect it
Remote control faulty
Replace it
Содержание Antea 24kW Range
Страница 39: ...39 A fig 21...
Страница 51: ...51 1 2 31 32 33 34 fig 31 9 Spare part list...
Страница 52: ...52 4 5 6 7 9 8 10 11 12 13 29 14 15 3 17 18 19 20 21 22 23 24 25 26 27 29 29 30 28 14 16 fig 32...
Страница 56: ...56...
Страница 57: ...57...
Страница 58: ...58 Affix your analyser print out here...
Страница 59: ...59...