medTester 5000C
Operators Manual
6-14
Follow directions, such as cycling power after reprogramming the scanner.
The scanner remains programmed after cycling power on the scanner and/or
the medTester.
Of the medTester autosequence prompts, you can configure eleven of them
to accept multiple labels when entering data from a bar code reader. The
eleven include the following:
medTester Bar Code Configurable Prompts
Prompt Name
1 OP
CODE
2 TYPE
3 MANF
4 LOC
5 MODEL
6 SERIAL
#
7 CONTROL
#
8 PHYSICAL
INSPECTION
9
PERFORMANCE WAVE COMMENTS
10 COMMENTS
11
NEXT TEST DUE DATE
Each bar code entry response to the prompt can include either single or
multiple labels. To access this customization feature, press the right arrow on
the customization menu display and select:
BARCODE
F2
For each prompt number and type, select either
F2
to accept a single
barcode label for data entered at this prompt, or select
F3
to accept
multiple label data entry. For example, you could enable multiple entry
input for prompt 10,
comments
. One bar code could indicate that the EUT
is dirty. Another could indicate that the EUT is greasy or dented. Any or
all of these conditions could be scanned into the comments section from
multiple bar code entries.
All of these entries are called strings, and multiple bar codes can combine
to form a string. A string ending in three spaces terminates the whole
string.
When finished with one field, you press
F4
to move to the next field
prompt or
F5
to end customization of these prompts.
Содержание medTester 5000C Operators
Страница 6: ......
Страница 32: ...medTester 5000C Operators Manual 1 20...
Страница 40: ...medTester 5000C Operators Manual 2 8...
Страница 46: ...medTester 5000C Operators Manual 3 6...
Страница 59: ...Biomedical Test System Manual Tests 4 4 13 Figure 4 1 Three Types of Line Voltage Measurements...
Страница 60: ...medTester 5000C Operators Manual 4 14 Figure 4 2 Case External Leakage...
Страница 61: ...Biomedical Test System Manual Tests 4 4 15 Figure 4 3 Case Internal Leakage...
Страница 62: ...medTester 5000C Operators Manual 4 16 Figure 4 4 External Leakage Current...
Страница 64: ...medTester 5000C Operators Manual 4 18 Figure 4 6 ECG Interlead Leakage...
Страница 65: ...Biomedical Test System Manual Tests 4 4 19 Figure 4 7 ECG Lead Isolation Test All Leads and Individual Leads...
Страница 66: ...medTester 5000C Operators Manual 4 20 Figure 4 8 Equipment Load Current...
Страница 67: ...Biomedical Test System Manual Tests 4 4 21 Figure 4 9 Power Cord Resistance Test...
Страница 68: ...medTester 5000C Operators Manual 4 22 Figure 4 10 External Resistance...
Страница 69: ...Biomedical Test System Manual Tests 4 4 23 Figure 4 11 Isolated Power System and Ground Fault Test...
Страница 70: ...medTester 5000C Operators Manual 4 24...
Страница 108: ...medTester 5000C Operators Manual 6 16...
Страница 114: ...medTester 5000C Operators Manual 7 6...
Страница 124: ...medTester 5000C Operators Manual 8 10...
Страница 178: ...medTester 5000C Operators Manual 11 14...
Страница 196: ...medTester 5000C Operators Manual 12 18...
Страница 210: ...medTester 5000C Operators Manual 13 14...
Страница 256: ...medTester 5000C Operators Manual 15 28...
Страница 274: ...medTester 5000C Operators Manual 16 18...
Страница 291: ...Biomedical Test System Index Index 3 installing 13 4 operating 13 7 setting baud rates 13 11 setting output ports 13 13...
Страница 292: ...medTester 5000C Operators Manual Index 4...