IJ PUMP OPERATION AND MAINTENANCE MANUAL
3-9
BO2660-01
ALIGNMENT SCHEDULE
1. First, verify that turbine is correctly
aligned with plant benchmark and fixed
in its permanent position.
2. Next, set up common centerline by
aligning centerline of high-speed pump
soleplates with centerline of turbine
shaft.
3. Then align centerline of low-speed
pump baseplate with common
centerline.
4. Finally, align centerline of any other
baseplate (or soleplates) which might be
in train with common centerline.
Figure 3-8 Baseplates and Soleplates in Train