Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3

The Pump sucks the liquid from the reservoir and pushes 

it into the tank, make sure the direction arrows are correct 

when fitting the hoses.

Thread the suction hose through the gland seen here.

Pull the hose out making sure not to kink during the 

operation.

When the hose is threaded through the lid, it will look 

like this. Make sure the hose reaches the bottom of the 

reservoir.

The filling cap is removed and then use the funnel to 

carefully fill the reservoir - do not overfill. fill when empty by 

adding 1Lt, do not fill to the brim.

It will look like this when finished.

Содержание TRANQUILITY

Страница 1: ...3 230v 50Hz Revised March 2015 PLEASE READ THIS MANUAL TO THE END BEFORE STARTING Updated MAY 2017 Floataway is a registered trademark of Cosine Limited 8 Ironside Way Hingham Business Park Hingham No...

Страница 2: ...nels 5 The tub 5 The ground noise isolation system 6 The skimmer and pre filter 7 The dome 7 The door 7 The hinges fitted to the door 8 The suction assembly and pump connections 9 The filter connectio...

Страница 3: ...r to ceilings below the float room if our advice has not been followed For commercial use the room must Have an emergency light Have appropriate fire warning and escape Have appropriate disabled use e...

Страница 4: ...d be in a waterproof terminal point or socket in some countries near to the location of the technical pack 1x 230v 50Hz supply 20A Check that the voltage of the pool is suitable for the supply install...

Страница 5: ...oth side facing you as shown below right The drawing shows the correct position of the heater panels The heater with a longer wire goes at the front of the product The cables run back to the con trol...

Страница 6: ...the floor due the GNIS will reduce these to give a superior float experience When installing the heavy GNIS board is placed down where the standard insulation would be fitted the insu lation panel is...

Страница 7: ...prevents debris such as earplugs entering the pump The skimmer s correct position is flush against the tub as shown below right Do not be afraid to give it a good strong hit to get it into its correct...

Страница 8: ...lly 6 Place a towel over the back of the dome to act as a spacer and close the door 7 The hinges can be fully adjusted The nuts securing the hinges to the tub are also used to adjust the height of the...

Страница 9: ...e clip driver 7mm provided Check before connecting that all the hose clips are aligned so that they can be tightened easily and that they can be easily reached in the future When the water has heated...

Страница 10: ...hut off the water supply when changing or servicing a pump Remove the ball of the water jet by rotating the retaining ring Remove the skimmer and the pre filter Once the jet fitting and the pre filter...

Страница 11: ...p ties Fit the level sensor to the reservoir bottle in the same way as the water level sensor The bottle and pump are fitted at the back of the tank The reservoir bottle holds 1Lt test the system for...

Страница 12: ...suction hose through the gland seen here Pull the hose out making sure not to kink during the operation When the hose is threaded through the lid it will look like this Make sure the hose reaches the...

Страница 13: ...nt disinfectant bottle optional There is a reservoir fitted to the techni cal pack but if you choose to use the bottles your disinfectant is supplied in the level sensor can be strapped to the bottle...

Страница 14: ...y SSR in this photo 4 MCBs mains circuits 5 Earth ground connectors 6 Supply N 230v 50Hz 20A N Terminal 2 7 Supply L 230v 50Hz 20A L Terminal 1 8 Control Power Supply 12v dc adjusted to 13 5v with no...

Страница 15: ...R Earth Supply Pump Water Heaters MCB 2 10A Pump PSU UV 1 5 5 5 6 5 Relay 1 PUMP 11 14 7 2 2 2 8 MCB 1 10A Heater 1 2 Heater 2 Pump SSR Heater SSR Relay Pump Relay 1 230V 50Hz 12v Power Supply Audio A...

Страница 16: ...Terminal 5 Neutral Terminal 2 Switched live for the Heaters Heater MCB 1 Heater bridge connection Terminal 8 The two heaters are connected together in series this is VERY important Visually check the...

Страница 17: ...e Temperature probe This is a cable mounted solid cylinder about 1 4 in diameter The temperature housing is pre filled with silicone grease Pass the probe through the cable tie CT and insert the metal...

Страница 18: ...lamp into the holder and re tighten the two bolts by hand to secure the lamp The remote for the lamps uses 2 4G Wi Fi it needs to be in range to control the lamps the lamps can only be adjusted when...

Страница 19: ...Bing bong sounder 12v pulsed Blue White Loudspeaker Audio speakers Green Back up battery 12v constant Red Auto Doser 12v pulsed Green Yellow Filter Sensor 12v switch Yellow Colour Therapy 12v constan...

Страница 20: ...ack Green The Music Speaker The sound is transmitted into the water with a sound transducer that excites the surface of the technical pack The wire has been provided to connect to this it uses an XLR...

Страница 21: ...o through any other units routers etc The LAN cable pairs are wired together The mic at the tank is connected via a clear tube To use the intercom lift the handset when lifted you can hear the custome...

Страница 22: ...ugs into the headphone socket of your source The operator must ensure that music is playing on the music source for it to work in the float Float Pool The system provides automatic fading down of the...

Страница 23: ...the connector and board B J W1 TK1 W3 TK2 tracks jumpers on the board A C F H F F Adaptor reception cable from control box to wall socket cable from remote to wall socket Remote Control Box G 3 5mm au...

Страница 24: ...nnection is inside the control box on the mother board as shown in this photo After testing and with the power off disconnect the remote control LAN RJ45 plug from the control box and install the remo...

Страница 25: ...tart or the time to the next pump pause is shown as is the temperature Very often the only action required is to start a new session To start a new session press START and then press The session will...

Страница 26: ...ns off after the end of the session to preserve its life REDOX and pH These are options which only show if fitted The redox ORP reading pH value are displayed Otherwise the dosing may be manual or aut...

Страница 27: ...you want then select using the then adjust You can cancel or return to the last screen at any time using the button You must use the back button below the display to exit the menu The screen asks if...

Страница 28: ...will fade up again two minutes before the end Off The Music is off but will fade in at the end of the float session to indicate the end Now you must use the back button to exit the menu and you are p...

Страница 29: ...introduce music or speech from any device with a headphone output for example a CD or MP3 player computer or iPod Recommended Values Temperature 35 4 degrees C T1 15 minutes the pump run time T2 60 M...

Страница 30: ...37 degrees before adding the salt To do this turn on the power to the system Using the remote control adjust function set the pump time t1 to a maximum and the dwell time t2 to minimum The water will...

Страница 31: ...filter housing with no cartridge and retest Sometimes a cartridge can be blocked with oils but still look clean This is also a good way to clear air from the system after servicing a pump The silent p...

Страница 32: ...t Floataway There is also a separate quick guide document on the operation of the remote Floataway is a registered trademark of Cosine Limited 8 Ironside Way Hingham Business Park Hingham Norfolk NR9...

Страница 33: ...s The Session settings menu if changed before or during a float session will effect that float session only and the program will return to the global settings automatically at the end of the float ses...

Страница 34: ...cancel Session Ending The Door is Open The Lights are On The Pump is On BACK to end now End Session now Press OK to select Or to cancel Refreshing the tank Pumping for mins Temperature C Redox Value...

Страница 35: ...p Settings Global Settings Status Screen Reset options Pump Settings Adjust Pump on time Pump dwell time Start pump now Stop pump now Save changes Press OK to Save Or to cancel Adjust Pump on time t1...

Страница 36: ...ve Or to cancel Global Settings More Options Normal Settings Adjust Autodose on time t3 Autodose refresh t4 Music Fadeout time Back Back Adjust Autodose on time t3 Change to Up Down Then OK Autodose o...

Страница 37: ...Menu Select Screen Session Settings Pump Settings Global Settings Status Screen Reset options Status Screen Session Count Filter Count Program version B27RJ Status Screen Reset Options Reset to Normal...

Страница 38: ...ol system allows you to adjust the times os many aspects of the pro gram to optimise your product to best work with your centre The controller is based around float sessions and standby mode The diagr...

Отзывы: