4
Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3
The Cables / Electrical Supply
The Data Cables:
The control system uses standard Industrial CAT5/6 LAN cable and RJ45 sockets. It must not be
part of a network but have it’s own dedicated cable. The cable should be installed with the control
box and remote. A second LAN cable is required for an intercom option. We recommend installing
a spare LAN cable at this time in case of damage to the cable.
2x Cat 5 or 6 LAN cables direct (no breaks/routers) from the back of the tank to the location of
the remote. The second is spare, but highly recommended. You need a 3rd if you have intercom or
think you may add it in the future.
Electricity Supply:
There should be a waterproof connection outlets for the single phase 230v 50 Hz. Supply. The
mains supply should be in a waterproof terminal point (or socket in some countries) near to the
location of the technical pack.
1x 230v 50Hz supply - 20A
Check that the voltage of the pool is suitable for the supply installed.
Connecting a 110 V pool to a 230 V supply or a 230 V pool to a 110 V supply will cause damage to
the pool components and may be dangerous. The supply should have a two-pole interrupter such
as a ceiling pull switch in the room. This interrupter must have a suitable current rating for the fuse
or breaker on each supply. The interrupter switch must be 2m (6’) from the water line of the pool.
Fusing and RCD (Residual Current Device) or GFCI :
• The pool should be supplied through it’s own RCD or GFCI (differential) with a trip current
of 30 mA / Class A and through an isolating switch.
• There must also be a fuse or circuit breaker in the line.
• For 230v installations the fuse should be 20 Amp with suitable cables.
We recommend that the electrical installation of the supply be done by a suitably qualified
electrician.