9
Floataway Installation Manual 230v 50Hz Tranquility 2017 - v3
The Suction Assembly and Pump Connections
Carry in the pump and the suction hose and place it behind
the tub, leaving at least 10” behind the tub to the back wall.
The 1 1/2” black rubber hose forms the suction assembly
which connects the tank outlet to the pump. The tub fitting
includes a plastic tube outlet and elbows
The photos show a 220v TE6 pump, depending on your
specification your pump may be different.
Fit the 1 1/2” rubber hose to the plastic tube and position
two hose clips as shown in the photo above right, pushing
the hose fully onto the pipe. Tighten the clips around the
hose using the hose clip driver (7mm) provided.
Check before connecting, that all the hose clips are aligned
so that they can be tightened easily and that they can be
easily reached in the future. When the water has heated
up, it is necessary to re-test the tension on these fittings
The Filter Connections and Back Panel
Bring in the back panel with its filter housing and auto-
dosing unit already fitted. Position it behind the tub.
You should leave at least 10” to the back wall for future
maintenance work.
Note: the filter inlet is at the top. The exit tube is at the
bottom of the filter housing. Connect the pump outlet to the
top of the filter, as shown in the photo on the right.
Then connect the hose from the UV filter (optional) to the
bottom of the filter housing as shown on the photo here :
Each tube connection has two clips for reliability.
Make sure all the pipe clips are tight.
Top