background image

Owner’s 

Guidebook

to the 

Best Spa Experience

on Earth

Raindance

Spas

raindancehottubs.com

2212 Buff alo Road

Johnson City, Tennessee 37604

(423) 477-7796

Содержание Spas

Страница 1: ...Owner s Guidebook to the Best Spa Experience on Earth Raindance Spas raindancehottubs com 2212 Buffalo Road Johnson City Tennessee 37604 423 477 7796...

Страница 2: ...2...

Страница 3: ...operation or maintenance contact Raindance Spa s Technical Support at Raindance Spa 866 996 2623 IMPORTANT Raindance Spa reserves the right to change specifications or designs without notification and...

Страница 4: ...4 SPA INFORMATION Date purchased Date installed Dealer name Dealer address Dealer telephone Spa model and serial number...

Страница 5: ...y Instructions 6 9 Site Selection 10 Startup Draining Diverter Valves 11 12 General Maintenance 13 Electrical Requirements and Servicing 14 15 Filter Maintenance 15 Care of Exterior and Chemicals 16 1...

Страница 6: ...educe the risk of injury to persons DO NOT REMOVE Suction Fittings 5 A pressure wire connector is provided on the side of the control box to permit connection of a minimum No 8 AWG 8 4mm solid copper...

Страница 7: ...100 degrees F are considered safe for a healthy adult Lower water temperatures are recommended for extended use exceeding 10 15 minutes and for young children B Since excessive water temperatures have...

Страница 8: ...erature of 98 6 F The symptoms of hyperthermia include dizziness fainting drowsiness lethargy and an increase in the internal temperature of the body The effects of hyperthermia include 1 Unaware of i...

Страница 9: ...oltage or other risk of injury REFER ALL SERVICING TO QUALIFIED SERVICE PERSONNEL When the power supply connections or power supply cord s are damaged if water is entering the audio video compartment...

Страница 10: ...the water is level and weight distribution is maintained equally Any deck patio or floor with adequate support should be suitable to carry the weight of the spa filled with water and people To determi...

Страница 11: ...ter cartridge filter housing assembly and lid Make sure filter cartridge is clean before installing Filter Housing Assembly Remove filter lid and rotate top filter housing counterclockwise and remove...

Страница 12: ...o drain the spa The T handles should always be in the open position allowing water flow before operating the spa The slice valves are located on the intake and discharge sides of the pump s they will...

Страница 13: ...ical handbook for further information on water chemistry and troubleshooting DRAINING THE WATER Locate drain hose near or around the equipment Remove cap and attach garden hose Open the back valve on...

Страница 14: ...s or extension cords are to be used in conjunction with the operation of this spa Supplying power to the spa which is not in accordance with these instructions will code both of the independent testin...

Страница 15: ...tions on the bottle Soak filter in a degreaser and power wash with a garden hose It is recommended to have a second filter which can be cleaned between filter changes This will enable you to quickly e...

Страница 16: ...bitor to use if your spa water has a high concentration of dissolved minerals The use of alcohol or any household cleaners other than those listed to clean the spa shell surface is NOT recommended DO...

Страница 17: ...elf to the rapid growth of bacteria The opposite is also true that high Ph levels have caustic reactions Chemicals affect pH levels and improper levels can even give a false Ph reading Therefore it is...

Страница 18: ...reduced The low speed mode on pump 1 is the only mode in which the ozonator will operate Ozone is an unstable form of oxygen and will react with oxidized bacteria much more rapidly than the chemicals...

Страница 19: ...he spa is not going to be used for a long period of time during a vacation or if the spa is winterized or if when water is being super chlorinated The spa pillows should be removed until the next use...

Страница 20: ...DO Use granulated chlorine bromine produced specifically for portable spas DO Make sure the spa is connected to a Ground Fault Circuit Interrupter GRCI protected circuit This GFCI is required by the N...

Страница 21: ...ur spa DO NOT Use the spa for long periods of time at temperatures over 104 F 40 C DO NOT Operate the spa without water Turn the circuit breaker off before emptying the spa and while it is empty DO NO...

Страница 22: ...type Any hot tub or spa installation must have a remote cut off switch that must be mounted at least five feet away from and within sight of the spa Be sure that your remote cut off is NOT installed...

Страница 23: ...23 Stereo Stereo Power Adapter JBL Topside Power Cord Speaker Pillows Stereo Components Spa Pack Spa Keypad Parts...

Страница 24: ...or Bleed Valve Bleed Valve Mini Jet Master Jet Mini Master Jet Standard Jet Master Jet Housing Standard Jet Housing Drop In Filter Standard Jet Housing Drain Bib 10 port manifold Gate Valve 6 port man...

Страница 25: ...25 Synthetic Cabinet Slatted Synthetic Cabinet Round Corner Slatted Cabinet Light Assembly Light Cabinet Pieces Light Components Subzero Insulation Parts Cont...

Страница 26: ...26...

Страница 27: ...gs will be preserved until next power up After the pump has been running for 2 minutes the current water temperature will be displayed DO NOT ENTER THE WATER Remove the spa cover and allow water to co...

Страница 28: ...orized agent of Raindance Spas This warranty is terminated if any extra components are installed after the manufac tured date No one has the authorization to add take away or make promise of performan...