DYNAVERT
®
L05
Instruction manual
4BS0516DE-EN/011
Stand/ issue: 25.07.03
23
3.6.2 Parameter
menu
P-OPERATION
Display text
Menu
Description
Value
1)
Range
Language
Commis.
Actual language
........ (“German” / ”English”)
A
Commis.
Application
........
(“ ... ”)
2)
Menu
Commis.
Visuble parameter level
........
(“ ... ”)
3)
P-TRAVEL CURVE DATA
v 3
Commis.
Rated speed v3
........
(0,02 ... 5,00 (m/s)
v Posi
Commis.
Positioning
speed
........
(0,02 ... 0,20 m/s)
BrkDis 3
Commis.
Braking distance out of v3
........
(0,5 ... 3000 cm)
StopDist
Commis.
Stopping
distance
........
(0,5 ... 3000 cm)
Position
Commis.
Positioning
distance
........
(0,0 ... 30,0 cm)
Accel.
Commis.
Acceleration
........
(0,25 ... 2,00 m/s
2
)
Decel.
Commis.
Deceleration
.......
(0,25 ... 2,00 m/s
2
)
P-MONITORING
v max
Commis.
Maximum
speed
........
(0,03 .... 5,50 m/s)
P-SYSTEM DATA
v/n
Commis.
Ratio vN / nN
........ (0,5-5,00 m/s,10-6000 rpm)
Dir-Sign
Commis.
Direction
default
........ (“down”/”up/down”/”up”)
Motor cw
Commis.
Travel direction of lift at clockwise
........
(“down”/”upf”)
rotary field at motor
Terminal 36
Commis.
Funktion of Terminal 36
........
(“up”,”reset”)
P-TRAVEL BEHAVIOR
P sp.ctr.
Commis.
P-part of the speed controller
........
(0,00 ... 320,00)
Tr sp.ctr.
Commis.
Readjustment time of speed controller
........
0 ... 9999 ms)
P sp.ct.pos
Commis.
P-part of n-controller/ position control
........
(0,00 ... 320,00)
Tr sp.ct.pos
Commis.
readjustment time n-controller/ position control....
0 ... 9999 ms)
P PosContr.
Commis.
P- part of position controller
........
0,00 ... 320,00)
Gear losses
Commis.
Gear
losses
........
(0 ... 100 %)
P-MOTOR DATA
n-motor
Commis.
Rated motor speed
........
4)
I-motor
Commis
Rated motor current
........
4)
f-motor
Commis.
Rated motor frequency
........
4)
V-motor
Commis.
Rated motor voltage
........
4)
cos phi
Commis.
cos phi of motor
........
4)
P-INVERTER DATA
V mains nom.
Commis.
Setting of line voltage
........
(230 ... 460 V)
P-INTERFACE
Op.-source
Commis.
Actual operation source
........ (“Termin.”,
”RS485”)
RS485-Prot
Commis.
Actual
protocol
........ (“DCP”)
Remark:
1) Noted value of the actually set values
2) Parameterisable applications are, for example, “
asynchron HTL1024
”,
“
synch.SAD ERN1387
”, “
asynchron DCP Res
”, “
synch.SAD DCP Res
”
and “
specific
” (set of parameters has been changed)
3) Possible menu-entries “
Commissioning
”, “
Standard
”, “
Expert
”
4) Performance-related values are not indicated (acc.to the motor type plate)
4)