Instruction
manual
DYNAVERT
®
L05
16
Stand/ issue: 25.07.03
4BS0516DE-EN/011
- X50
Connection
(SUBD 9-pole., plug)
1
signal
(receive)
RXD
2
signal (transmit)
TXD
3
4
Mass
(Ground)
M
5
6
7
8
9
DYNAVERT
®
L05
Bem.:
- „Null-Modem“-cable, connect the cable screening at both ends (SUB-D9-housing)
Fig. 8: RS232-Interface (IMS)
- X51
Connection
(SUBD 9-pole, socket)
1
2
external
short
3
4
Mass
(Ground)
M
5
signal
RS485 A
6
7
signal
inverted
RS485 B
8
Mass
(Ground)
M
9
DYNAVERT
®
L05
Fig. 9: RS485-Interface (DCP)
HTL-encoder
- X101
Connection
(SUBD 9-pole, socket)
HTL-track A
HTL-A
1
HTL-track B
HTL-B
2
3
Supply
voltage
+15 V
4
Mass
(Ground)
M
5
6
7
8
Mass
(Ground)
M
9
DYNAVERT
®
L05
Note:
- If the encoder cables are made by customer, cable shield to be connected only at the inverter-side
- In case of system supply (inverter and motor), the complete encoder cables are supplied by Loher
(other encoder cables possible upon request).
- Encoder cable HTL for “clockwise encoder-plugs“:
- 10 m
Serial no. 0213630
-
- 20 m
0213631
- Encoder cable HTL for “anti-clockwise encoder-plugs“:
- 10 m
0213632
-
- 20 m
0213633
- Encoder cable HTL for encoder with unsealed cable ends:
- 10 m
0225557
Fig. 10: Connections HTL- encoder