517766
March 2003
- 25 -
7.
(00000111) Phase 1 to 6 - Display Module Fault
The Display module has found a memory fault.
Primary Source:
Display Module.
Action:
Replace Display module.
8.
(00001000) Phase 1 - Display Module Fault
The Display micro has not been able to start up correctly.
Primary Source:
Display Module.
Action:
Turn off at the wall and on again after 5 seconds and try again.If still
faulty replace the Display Module.
9.
(00001001) Phase 1 to 6 Size Switch Error
The Display size switch setting does not match that stored in the memory.
Primary Source:
Display Module Phase 1,2 & 3.
Action:
If the Display module for Phase 1, 2 or 3 has just been inserted into a console
housing, then check that the two size switch plungers accurately locate onto the
console housing. If this fault has appeared during normal operation of the
machine, check for condensation damage, check the size switch or replace the
Display module.
Secondary Source:
Motor Controller module.
Action Phase 1, 2 &3:
If the Motor Controller module has been changed from one size machine to
another, then the size switch settings in the memory will have to be reset. This can
be done by entering and exiting the Option Adjustment mode. Push and hold
START/PAUSE then push POWER button.
Action Phase 4 Series 8, Phase 5 Series 9 / 10 & Phase 6 Series 11:
Reselect the size of the machine by using the SIZE SETTING MODE. Push and
hold the WATER TEMP UP button then press the POWER button. To select the
size of the machine. Push the temperature up button until the cold LED is on for
5kg machines, push the water level up button until the low water level LED is on for
the 6kg machines, push the SPIN SPEED UP button until the hold LED is on for
7kg machines.
10.
(00001010) Phase 1 to 6 Temperature Sensor (Thermistor) Error
The temperature sensor may be open circuit or the ambient temperature is below
minus (10oC) 50
°
F. This fault is only applicable in the Intuitive Washer and the
GW models.
Primary Source:
Thermistor.
Action:
Replace Thermistor.
11.
(00001011) Phase 1 to 6 - Pressure Sensor Fault
While measuring the water level, the Motor Controller micro has detected a
negative pressure. Reconnecting the pressure tube to the pressure sensor while
the bowl has been partly filled with water may have caused this.
Primary Source:
Pressure Tube.
Action: