PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
MVWC200X, MVWC400X, MVWC450X,
MVWX500X, MVWX600X, MVWX700X,
MVWC300X, MVWX550X
Electrical:
A 120 volt, 60 Hz., AC only, 15- or 20-amp,
fused electrical supply is required. A time-delay fuse
or circuit breaker is recommended. It is recommended
that a separate circuit serving only this washer be
provided.
Washer dimensions
Because Whirlpool Corporation policy includes a continuous commitment to improve
Dimensions are for planning purposes only. For complete details, see Installation
our products, we reserve the right to change materials and specifications without notice.
Instructions packed with product. Specifications subject to change without notice.
Ref. W10240509C
02/2011
For closet installation, with a door, the minimum ventilation openings in the
top and bottom of the door are required. Louvered doors with equivalent air
ventilation openings are acceptable.
42"
(1067 mm)
27"
(686 mm)
27
1
/
2
"
(699 mm)
3"
(76 mm)
3"
(76 mm)
24 in.
2
(155 cm
2
)
48 in.
2
(310 cm
2
)
17"
(432 mm)
1"
(25 mm)
1"
(25 mm)
5"
(126 mm)
14" max.
(356 mm)
Dimensions show recommended spacing allowed, except for closet door ventilation
openings which are minimum required. This washer has been tested for installation with
spacing of 0" (0 mm) clearance on the sides. Consider allowing more space for ease of
installation and servicing, and spacing for companion appliances and clearances for walls,
doors, and floor moldings. Add spacing of 1" (25 mm) on all sides of washer to reduce
noise transfer. If a closet door or louvered door is installed, top and bottom air openings in
door are required.
DRAIN SYSTEM
Minimum diameter for a standpipe drain: 2" (51 mm).
Minimum carry-away capacity: 17 gal. (64 L) per minute.
Top of standpipe must be at least 39" (990 mm) high;
install no higher than 96" (2.44 m) from bottom of washer.
If you must install higher than 96" (2.44 m), you will need
a sump pump system.
Wall standpipe drain system
Laundry tub drain system
Minimum capacity: 20 gal. (76 L). Top of laundry tub must be at least 39" (990 mm)
above floor; install no higher than 96" (2.44 m) from bottom of washer.
IMPORTANT:
To avoid siphoning, no more than 4.5" (114 mm) of drain hose
should be inside standpipe or below the top of wash tub. Secure drain hose
with cable tie.
Floor drain system
Floor drain system requires additional parts. Minimum
siphon break: 28" (710 mm) from bottom of washer.
Floor standpipe drain system
See requirements for floor standpipe drain system.
4
1
/
2
"
(114 mm)
4
1
/
2
"
(114 mm)
4
1
/
2
"
(114 mm)
30"
(762 mm)
30"