517766
March 2003
- 37 -
Action:
Replace Display module.
Secondary Source:
Motor Controller module.
Action:
Replace Motor Controller module. If the new Motor Controller module corrects the
fault, refit the original Display module.
107.
(01101011) Phase 2 to 6 - Motor Controller module Reset Error
The Display Module has detected that the Motor Controller module has reset when
it should not have. This can be due to a Motor Controller module supply
disturbance or microprocessor failure.
Primary source:
Motor Controller module.
Action:
Replace Motor Controller module.
108.
(01101100) Coms CRC error Phase 6 IW Display only See fault code 106
127.
(01111111) Phase 5 – Machine Set up Error
The display module has been fitted to the wrong model, size and or phase
machine! eg. Phase 5 Display cannot be fitted to a Phase 4 Motor Controller! The
colour of the modules is a good indicator, part numbers are also very important.
130.
(10000010) Phase 1 to 6 Single Rotor Position Sensor Error
The Motor Controller has found an error in the pattern received from the Rotor
Position Sensor. Likely causes of this fault are a bad connection on the harness
between the Rotor Position Sensor and the Motor Controller, or a faulty Rotor
Position Sensor.
Primary Source:
Wiring.
Action:
1)
Check for corrosion on the edge connector of the Rotor Position Sensor and
the Motor Controller module connector.
2)
Check the contacts on the rotor positional sensor end of the hall harness to
see if any have been damaged. (Each set of contacts in the socket has two
wipers. If the distance between these wipers varies between different
contacts, replace the rotor positional sensor harness).
Secondary Source:
Rotor Position Sensor.
Action:
Check the Rotor Position Sensor with an R.P.S. tester. Replace if faulty.
Tertiary Source:
Motor Controller module.
Action:
Replace Motor Controller module.
131.
(10000011) Phase 1 to 6 - Repetitive Rotor Position Sensor Error
This fault is similar to fault number 130 above but differs slightly in that it is a
continuous condition. See fault code 130 for service procedure.
132.
(10000100) Phase 1 to 4 - Single Current Trip
The Motor Controller has detected excess current in the motor or electronic
switches. This fault has occurred momentarily.
Primary Source:
Wiring.
Action:
Check the wiring connections from the Motor Controller to the Stator
and the Rotor Position Sensor.