517766
March 2003
- 15 -
16.2
Smartdrive Diagnostic Table
To use this table, firstly enter Diagnostic Mode. The different levels of information can be
extracted by using the Spin Speed up and down buttons.
Diagnostic
Mode
Spin Speed LEDs
Fast Med Slow Hold
Diagnostic Info Displayed
0
OFF OFF OFF OFF
Last User Warning Number
1
OFF OFF OFF ON
Last User Warning Cycle Position
2
OFF OFF ON
OFF
HVDC setting (used by auto WL sense agitate)
3
OFF OFF ON
ON
Fault Code at last fault (if within the last 8
cycles)
4
OFF ON
OFF OFF
OOB status
5
OFF ON
OFF ON
Cycle count at last fault (low byte)
6
OFF ON
ON
OFF
Cycle count at last fault (high byte)
7
OFF ON
ON
ON
Cycle position at last fault
8
ON
OFF OFF OFF
Water Temp (deg C)
9
ON
OFF OFF ON
Cycle count (low byte)
10
ON
OFF ON
OFF
Cycle count (high byte)
11
ON
OFF ON
ON
Motor speed (rpm/10)
12
ON
ON
OFF OFF
Water Level
13
ON
ON
OFF ON
EEPROM version number
14
ON
ON
ON
OFF
Software Version number
15
ON
ON
ON
ON
(F&P development use only)
16.3
USER WARNINGS
There are a number of warnings which are generally caused by the user or poor
installation. These warnings should be corrected by the user. Smartdrive signals user
warnings by flashing LEDs and a rippling set of 5 beeps repeated every 6 seconds. This is
the same tone that is heard when Smartdrive is first plugged into the mains power. Some
warnings are indicated by the wash progress LEDs flashing and no user warning tone,
(Restart or Recycle mode). Most of this information is available to the user in the ‘Use and
Care Manual’
Содержание ecosmart GWL11