517766
March 2003
- 32 -
45.
(00101101) Phase 5 Display Memory Check Fault
On power up, the display has checked its memory against a known reference and
found differences.
Primary Source:
Display Module.
Action:
Replace Display Module.
46.
(00101110) Phase 5 IW – Display EEPROM Check
The Intuitive Display has detected a problem with its internal EEPROM.
Primary Source:
IW Display Module
Action:
Replace IW Display Module
47.
(00101111) Phase 2 and 3 - Basket Dis-engage Fault
While carrying out a Basket check, the Motor Controller module has found that the
basket is not engaged even though the pressure sensor indicates that the Tub is
empty. The Motor Controller module continues to check for 2 minutes. During this
time the module has not been able to determine a valid tub status and so displays
this fault. This fault differs from fault code 40 in that a valid tub status could not be
determined. The first two areas to check are the clutch and the pressure tube. If
these two appear correct, then the fault could be with the pressure sensor in the
Motor Controller module.
Primary Source:
Mechanical.
Action:
1)
Check that there are no clothes or other foreign objects preventing the clutch
from re-engaging.
2)
Next check that the pressure tube has not come off and that it is not kinked.
Secondary Source:
Motor Controller module.
Action:
Replace Motor Controller module, if the above checks out without fault.
48.
(00110000) Phase 2 to 6 - Hot and Cold Valve Faulty
The Motor Controller module has measured voltages from the valve diagnostic
circuit that indicate both the hot and cold valves are faulty. The most likely cause is
that the valve harnesses have not been connected correctly or the valve is open
circuit.
Primary Source:
Wiring.
Action:
Check the valve harnesses are correctly fastened to the valves or the pins are not
bent backwards.
Secondary Source:
Water Valves.
Action:
Check the valve coils are not faulty (open circuit).
Tertiary Source:
Motor Controller module.
Action:
Replace the Motor Controller module.
49.
(00110001) Phase 2 to 6 - Cold Valve Faulty (proportional)
The Motor Controller module has measured a voltage from the valve diagnostic
circuit that indicates the cold valve is faulty. The most likely cause is that the valve
harness has not been connected correctly or the valve is open circuit. See fault
code 48 for service procedure.