Check bowl is fully pumped out. Remove pressure tube from pressure
sensor, clear pressure tube of any water and reconnect tube.
2)
If fault is still present, replace the Motor Controller module.(Display Module
Phase 1)
12.
(00001100) Phase 1 to 6 - Flood Protection Error
The Motor Controller module has found the water level to be above the flood level
and tried to pump the excess water out. (Under extremely high flow rate conditions
the machine may overfill during the “top-up” routine in agitate.) After pumping for
30 seconds, it has been unable to lower the water level below the flood level.
Either the water valves have stuck on and are letting water in at a flow rate that is
higher than the pump can handle, or the pump is blocked and can’t remove the
excess water.
Primary Source:
Water Valves.
Action:
If the water valves are on continuously, check that the water valves turn off
mechanically (remove power from machine).
Secondary Source:
.Pump system
Action:
Check pump for blockage and drain hose for correct height and kinking
Tertiary Source:
Motor Controller module. (Display Module Phase 1)
Action:
If water valves are being driven on electrically, replace Motor Controller
module. (Display Module Phase 1)
13.
(00001101) Phase 1 – Pump Fault
The Display module has detected that the pump is on when it should be off.
Action:
1.
The pump is fitted with a thermal cut out device. Check if this device has
been activated. If it has wait until the pump cools down before restarting.
Check for any pump blockage and condition of pump before attempting to
restart. i.e. pump seizure.
2.
Check for open circuit pump windings. Check the resistance of the pump.
3.
Check the pump harness or the connectors for an open circuit.
4.
Replace the Display Module.
14.
(00001110) Phase 1 – Pump Connection Fault
The Display Module has detected that the pump is not on when it should be.
Primary Source
– Pump
Action:
1.
The pump is fitted with a thermal cut out device. Check if this device has
been activated. If it has wait until the pump cools down before restarting.
Check for any pump blockage and condition of pump before attempting to
restart. i.e. pump seizure.
2.
Check for open circuit pump windings. Check the resistance of the pump.
3.
Check the pump harness or the connectors for an open circuit.
4.
Replace the Display Module.
15.
(00001111) Phase 1 – Display Module Fault
The Display Module has read an incorrect voltage on the pump circuit
Primary Source:
Display Module
Action: